Results 121 to 130 of about 1,086,533 (280)
A Design of a High-Performance Analog Front-End for Passive UHF RFID Tag EPC C1G2
This paper introduces a high-performance analog front end for passive UHF RFID tag compatible with the EPC Class-1 Generation 2 (EPC C1G2) standard protocol.
Smail Hassouni, Hassan Qjidaa
doaj
ABSTRACT Background The delipid extracorporeal lipoprotein filter from plasma (DELP) treatment can effectively reduce blood lipid, increase blood flow, and improve neurological deficits in patients with acute ischemic stroke (AIS). However, its effect on vision and retinal microcirculation in stroke patients has never been reported.
Ning Li +9 more
wiley +1 more source
Realisation of High-Frequency DRO Oscillators with Mosfet Transistors for Sub-MMWAVE Band
In high-frequency electronics, optimizing RF oscillators performance is essential, especially as applications reach into wide frequency bands. This article describes proposed clock generators for UWB sensor systems based on oscillators with dielectric ...
Jurík Patrik +2 more
doaj +1 more source
ABSTRACT Introduction Cognitive impairment and exercise intolerance are common in dialysis patients. Cerebral perfusion and oxygenation play a major role in both cognitive function and exercise execution; HD session per se aggravates cerebral ischemia in this population. This study aimed to compare cerebral oxygenation and perfusion at rest and in mild
Marieta P. Theodorakopoulou +10 more
wiley +1 more source
ABSTRACT Background Chronic kidney disease is a growing public health problem worldwide, and the number of patients requiring renal replacement therapy is steadily increasing. Türkiye has experienced a similar rise in both the incidence and prevalence of renal replacement therapy over the past decades; however, national‐level projections of future ...
Arzu Akgül +2 more
wiley +1 more source
This letter presents the principles and techniques of active optical clock, a special laser combining the laser physics of one-atom laser, bad-cavity gas laser, super-cavity stabilized laser and optical atomic clock. As an example, a compact version of active optical clock based on thermal Strontium atomic beam shows a quantum-limited linewidth of 0.51
openaire +2 more sources
Revealing the structure of land plant photosystem II: the journey from negative‐stain EM to cryo‐EM
Advances in cryo‐EM have revealed the detailed structure of Photosystem II, a key protein complex driving photosynthesis. This review traces the journey from early low‐resolution images to high‐resolution models, highlighting how these discoveries deepen our understanding of light harvesting and energy conversion in plants.
Roman Kouřil
wiley +1 more source
Mapping the evolution of mitochondrial complex I through structural variation
Respiratory complex I (CI) is crucial for bioenergetic metabolism in many prokaryotes and eukaryotes. It is composed of a conserved set of core subunits and additional accessory subunits that vary depending on the organism. Here, we categorize CI subunits from available structures to map the evolution of CI across eukaryotes. Respiratory complex I (CI)
Dong‐Woo Shin +2 more
wiley +1 more source
Enteropathogenic E. coli (EPEC) infects the human intestinal epithelium, resulting in severe illness and diarrhoea. In this study, we compared the infection of cancer‐derived cell lines with human organoid‐derived models of the small intestine. We observed a delayed in attachment, inflammation and cell death on primary cells, indicating that host ...
Mastura Neyazi +5 more
wiley +1 more source