Results 121 to 130 of about 9,683 (289)

Waveguide Photoactuators: Materials, Fabrication, and Applications

open access: yesAdvanced Robotics Research, EarlyView.
Waveguide photoactuators convert guided light into mechanical motion. Their tethered‐flexible design enables minimally invasive surgery and confined‐space robotics. This review aims to guide materials selection, device design, and system integration, accelerating the transition of waveguide photoactuators from laboratory prototypes to versatile ...
Minjie Xi   +4 more
wiley   +1 more source

Development and evaluation of TDR probe for water rational management on substrates used in forest seedlings production

open access: yesRevista Ambiente & Água, 2009
Time Domain Reflectometry (TDR) is a reliable technique to estimate in situ moisture content in different types of materials using probes. The forest seedlings production implies in a comprehensive and empirical process of water management applied to the
Lucas Masayuki Sato   +3 more
doaj   +1 more source

Analytical modeling of open-ended coaxial probe - a review

open access: yes, 2008
An open-ended coaxial probe is a probe consists of inner and outer conductors with radius, respectively. The open end of the coaxial line is terminated by a semi-infinite sample on a ground plane.
Yeow, You Kok   +2 more
core  

Functional Fibers in Soft Robotics: Advances in Material, Structural, and Systemic Tactics

open access: yesAdvanced Robotics Research, EarlyView.
Fiber‐form robotic systems offer a scalable pathway toward embodied intelligence in soft robotics. This review surveys functional fibers as material, structural, and systemic elements, highlighting advances in responsive materials, architectural programing, and fabrication strategies.
Joonhee Won   +5 more
wiley   +1 more source

Optimization of Magnetic Milli‐Spinner for Robotic Endovascular Intervention

open access: yesAdvanced Robotics Research, EarlyView.
This work presents the design optimization of a multifunctional magnetic milli‐spinner for high‐speed propulsion and efficient clot debulking. The optimized design achieves an ultrafast swimming velocity of 55 cm/s (≈175 body lengths/s) in saline water, enabling stable upstream swimming against strong physiological flows and establishing magnetic milli‐
Lu Lu   +3 more
wiley   +1 more source

Microscale Mapping of Fiber Strain and Damage in Composite Wrinkled Laminates Using Computed Tomography Assisted Wide‐Angle X‐Ray Scattering

open access: yesAdvanced Science, EarlyView.
This study combines full‐field tomography with diffraction mapping to quantify radial (ε002$\varepsilon _{002}$) and axial (ε100$\varepsilon _{100}$) lattice strain in wrinkled carbon‐fiber specimens for the first time. Radial microstrain gradients (−14.5 µεMPa$\varepsilon \mathrm{MPa}$−1) are found to signal damage‐prone zones ahead of failure, which ...
Hoang Minh Luong   +7 more
wiley   +1 more source

Comparative measurement of dielectric properties of food powders at microwave frequencies by open-ended coaxial probe and cavity perturbation technique

open access: yes, 2023
International audienceThe dielectric properties of paprika, curry, corn starch and semi-skimmed milk, with moisture contents in the range of 5.63 to 7.74 % (dry basis), were determined by open-ended coaxial probe and cavity perturbation technique.
Frabetti, Ana, Caroline   +6 more
core   +1 more source

A Review on Catalytic Nanostructured Electrodes for Wearable and Implantable Abiotic Glucose Fuel Cells

open access: yesAdvanced Science, EarlyView.
This review identifies current and future directions in abiotic nanostructured catalysts to develop reliable and sustainable glucose fuel cells to power the next generation of bioelectronic devices. ABSTRACT The global rise in incidence of chronic diseases has led to the demand for innovative solutions that help patients manage their conditions with ...
Asghar Niyazi   +3 more
wiley   +1 more source

Calculation of the Inductance of Plasma Column at PF-1000 Device with Assumed Current Distribution

open access: yesActa Polytechnica, 2013
Processed data is taken from the D-D fusion reaction experiments on PF-1000 at IFPILM Warsaw, operating with 2 MA, 1011 neutron yield, using interferometry, temporal resolved neutron diagnostics, magnetic probe diagnostics and X-ray diagnostics.
Jiri Kortanek, Pavel Kubes
doaj  

Home - About - Disclaimer - Privacy