Results 181 to 190 of about 7,734 (252)

Active Electromagnetic Interference Suppression for MRI and Proton Resonance Frequency Shift Thermometry During MRI‐Guided Microwave Ablation

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a software‐based active electromagnetic interference (EMI) suppression (AES) framework on whole‐body multi‐channel MRI systems for reliable MRI and MR thermometry during MRI‐guided microwave ablation (MWA). Methods In addition to primary imaging coils, an unloaded standard body array coil was positioned outside the imaging ...
Qing Dai   +5 more
wiley   +1 more source

Thin-Film-Engineered Self-Assembly of 3D Coaxial Microfluidics with a Tunable Polyimide Membrane for Bioelectronic Power. [PDF]

open access: yesNanomicro Lett
Egunov AI   +12 more
europepmc   +1 more source

Design, Analysis, and Experimental Validation of a Variable‐Gap Magnetorheological Damper for Seat Suspension

open access: yesInternational Journal of Mechanical System Dynamics, EarlyView.
ABSTRACT To address the dual challenges of routine driving vibration and impact loads in vehicle seat suspensions, a novel variable‐gap magnetorheological damper (VGMRD) is proposed. By combining a tapered piston with a conformal variable‐diameter cylinder, stroke‐dependent, dual‐mode damping characteristics are achieved without the need for complex ...
Min Wei   +4 more
wiley   +1 more source

Anisotropic Initial Damage and Its Effect on Tensile Response of Plain Concrete

open access: yesInternational Journal for Numerical and Analytical Methods in Geomechanics, EarlyView.
ABSTRACT Damage is often described as isotropic, implying that a scalar value describes its initial state. However, the prior micro‐cracking pattern at points of an existing building, that is, the initial damage, may be oriented by a preload. The degradation of the Volume Element due to oriented preloads shall be described as anisotropic and ...
A. Fau   +3 more
wiley   +1 more source

Magnetic Probe Measurements on a Coaxial Plasma Gun

open access: yesKakuyūgō kenkyū, 1964
Be, Suckhi, Nakano, Yoshiei
openaire   +2 more sources

Polylactide/Graphene Nanoplatelet Composites for Advanced Functional Applications

open access: yesPolymer Composites, EarlyView.
Polylactide/Graphene nanoplatelet composites for advanced functional applications. ABSTRACT This study investigates the structure–property relationships of polylactide (PLA) nanocomposites containing graphene nanoplatelets (GNP) and trimellitic anhydride‐modified GNPs (TMA‐GNP).
Shivanthi Dharmarathna   +5 more
wiley   +1 more source

Electrospun conducting polymers: recent trends and the transition towards a sustainable future

open access: yesPolymer International, EarlyView.
This review discusses the electrospinning of conducting polymers, detailing procedures, fibrous morphologies, improved properties, applications in electronics, and challenges, while outlining future directions for nanofibre‐based devices in various fields.
Xenofon Karagiorgis   +3 more
wiley   +1 more source

Current Trends and Future Prospects of Integrating Electrospinning With 3D Printing Techniques for Mimicking Bone Extracellular Matrix Scaffolds

open access: yesJournal of Polymer Science, Volume 63, Issue 6, Page 1481-1504, 15 March 2025.
ABSTRACT This article presents a review of the recent findings on the combination of electrospun nanofibers and three‐dimensional (3D)‐printed structures for extracellular matrix (ECM) scaffolds for bone tissue engineering. We explore the synergy between electrospinning (ES), which produces highly porous, fibrous structures from materials like collagen
Kardo Khalid Abdullah, Kolos Molnár
wiley   +1 more source

Home - About - Disclaimer - Privacy