Results 201 to 210 of about 1,674,359 (231)

Observation of Direct and Indirect Effects of Surface Stabilizer on the Attenuation Coefficient of CdTe Nanoplatelet Films. [PDF]

open access: yesNanomaterials (Basel)
Bubenov S   +7 more
europepmc   +1 more source

Electrically Tunable On‐Chip Topological Photonics with Integrated Carbon Nanotubes

open access: yesAdvanced Functional Materials, EarlyView.
This work demonstrates electrically tunable on‐chip topological THz devices by integrating 2D carbon nanotube (CNT) sheets with valley‐Hall photonic crystals, enabling broadband transmission modulation (71% modulation depth) and tunable narrowband filtering (0.54 GHz shift) through electrically induced thermal tuning. This advancement paves the way for
Jifan Yin   +7 more
wiley   +1 more source

Cholesterol tunes lipid bilayer interactions. [PDF]

open access: yesRSC Adv
Liu W   +7 more
europepmc   +1 more source

Peptide Sequencing With Single Acid Resolution Using a Sub‐Nanometer Diameter Pore

open access: yesAdvanced Functional Materials, EarlyView.
To sequence a single molecule of Aβ1−42–sodium dodecyl sulfate (SDS), the aggregate is forced through a sub‐nanopore 0.4 nm in diameter spanning a 4.0 nm thick membrane. The figure is a visual molecular dynamics (VMD) snapshot depicting the translocation of Aβ1−42–SDS through the pore; only the peptide, the SDS, the Na+ (yellow/green) and Cl− (cyan ...
Apurba Paul   +8 more
wiley   +1 more source

A Smart Bio‐Battery Facilitates Diabetic Bone Defect Repair Via Inducing Macrophage Reprogramming and Synergistically Modulating Bone Remodeling Coupling

open access: yesAdvanced Functional Materials, EarlyView.
This research presents a novel implantable bio‐battery, GF‐OsG, tailored for diabetic bone repair. GF‐OsG generates microcurrents in high‐glucose conditions to enhance vascularization, shift macrophages to the M2 phenotype, and regulate immune responses.
Nanning Lv   +10 more
wiley   +1 more source

Acute effects of tissue flossing on ankle range of motion in athletes with limited ankle dorsiflexion: a randomized controlled trial. [PDF]

open access: yesBMC Sports Sci Med Rehabil
Daneshmandi H   +5 more
europepmc   +1 more source

High‐Spatiotemporal‐Resolution Transparent Thermoelectric Temperature Sensor Arrays Reveal Temperature‐Dependent Windows for Reversible Photothermal Neuromodulation

open access: yesAdvanced Functional Materials, EarlyView.
Thermoelectric temperature sensors are developed that directly measure heat changes during optical‐based neural stimulation with millisecond precision. The sensors reveal the temperature windows for safe reversible neural modulation: 1.4–4.5 °C enables reversible neural inhibition, while temperatures above 6.1 °C cause permanent thermal damage.
Junhee Lee   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy