Results 161 to 170 of about 146,612 (216)
Some of the next articles are maybe not open access.

Discharge Coefficient for Siphon Spillways

Journal of Irrigation and Drainage Engineering, 2013
AbstractThe study deals with the discharge coefficient for siphon spillways based on the results of experimental methods and numerical simulations. Siphon spillways are used as the outlet in reservoirs to control the incoming flood flows. A scaled plexiglass model of a siphon was fabricated and tested in the laboratory flume to determine the siphon ...
Rahim Tadayon, Amruthur S. Ramamurthy
openaire   +1 more source

Coefficients of Discharge at the Aperatures of Engines

SAE Technical Paper Series, 1995
<div class="htmlview paragraph">This paper reports on the experimental evaluation of certain aspects concerning the mathematical modelling of pressure wave propagation in engine ducting. A particular aspect is the coefficient of discharge of the various ports, valves or apertures of the ducting connected to the cylinder of an engine or to the ...
G. P. Blair   +4 more
openaire   +1 more source

Assessing effects of wind speed and wind direction on discharge coefficient of sidewall opening in a dairy building model - A numerical study

Computers and Electronics in Agriculture, 2019
The discharge coefficient (Cd) of an opening is an important parameter in the application of the orifice equation to calculate the airflow rate of naturally-ventilated buildings.
Qianying Yi   +5 more
semanticscholar   +1 more source

Nozzle Discharge Coefficient

2015
Four ASME (PTC 6) flow nozzles were manufactured together with upstream and downstream pipework in two pipe sizes. Throat and wall tappings were used. The flow nozzles were calibrated in water and in high-pressure nitrogen at 20 and 60 barg. The wall-tapping data are in excellent agreement with the discharge-coefficient equation in ISO 5167-3:2003: all
openaire   +1 more source

Orifice Discharge Coefficient

2015
The discharge coefficient is required to measure flow using a differential-pressure meter. This chapter considers the discharge-coefficient equation for orifice plates: its history, some older equations, the database collected mostly in the 1980s and the analysis.
openaire   +1 more source

The discharge coefficient of effervescent atomizers

Experimental Thermal and Fluid Science, 2010
Abstract The paper contains the results of experimental investigation of air–water atomization process in effervescent nozzles with internal mixing. The aim of study was analysis of pressure drop and discharge coefficient. The study was carried out at liquid flow rates changed from 0.0014 to 0.011 [kg/s] and gas flow rates from 0.00015 to 0.0065 [kg ...
M. Ochowiak   +2 more
openaire   +1 more source

Discharge coefficient of subsurface weirs

Proceedings of the Institution of Civil Engineers - Water Management, 2014
Experimental and numerical studies were performed to examine the relationship between the hydraulic properties and physical dimensions of a subsurface weir system and the discharge over it under steady-state conditions. Experimental modelling was based on a laboratory-scale physical sand-tank model, within which a subsurface dam and weir structure was
Abdorreza Kabiri-Samani   +1 more
openaire   +1 more source

Discharge coefficients of diaphragms and nozzles

Measurement Techniques, 1959
1. The table of initial discharge coefficients of diaphragms should be corrected by taking the coefficient value 0.646 (instead of 0.645) for the 0.35 modulus. 2. The functional dependence of the initial discharge coefficient on the modulus of flow-contraction devices, represented by a polynomial of the 4th degree, yields deviations from
openaire   +1 more source

Hydraulic performance of hydrofoil-crested stepped spillways: air inception point and discharge coefficient

Journal of Applied Water Engineering and Research
This study evaluates the air inception point and discharge coefficient (Cd) in Hydrofoil-Crested Stepped Spillways (HCSS) through laboratory experiments on 60 models. The experiments varied five hydrofoil formation indices (t), four chute slopes (θ), and
Ehsan Afaridegan   +2 more
semanticscholar   +1 more source

Laboratory investigation of the Discharge Coefficient of flow in arced labyrinth weirs with triangular plans

Flow Measurement and Instrumentation, 2018
Weirs play a decisive role in the safety of dams. There are different types of weirs including labyrinth, linear, arced, piano key, etc. Arced weir is an arc of a circle which makes possible an increase in the effective length of the weir crest at a ...
Reza Monjezi   +4 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy