Results 51 to 60 of about 1,505,311 (244)
Three-dimensional trans-esophageal echocardiographic evaluation of atrial Septal defects : a pictorial essay [PDF]
This pictorial assay illustrates the methodology of evaluating the atrial septal defects by three dimensional transesophageal echocardiography with the help of representative images.
Shrivastava, Sameer +2 more
core
Although transthoracic two-dimensional echocardiography can detect dilation of the coronary arteries, the reliability of this technique in the detection of coronary artery stenosis is still doubtful.
T Hozumi +6 more
core +1 more source
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius +9 more
wiley +1 more source
Two-dimensional (2D) echocardiogram with the aid of color Doppler and pulsed Doppler allows one to record blood flow waveforms in several structures of the heart.
Luciane Alves Rocha +3 more
doaj +1 more source
Heart failure (HF) is a leading cause of cardiovascular morbidity and mortality. However, its symptoms and signs are not specific or can be absent. In this context, transthoracic echocardiography plays a key role in diagnosing the various forms of HF ...
Simona Sperlongano +11 more
doaj +1 more source
ABSTRACT Background Transcatheter closure (TCC) of sinus venosus defects (SVD) using balloon‐expandable covered stents is an emerging alternative to surgery. ZephyrCS (Sahajanand Laser Technologies, Gandhinagar, India) is available in long lengths to suit SVD closure.
Pramod Sagar +3 more
wiley +1 more source
Echocardiography is an important first-line investigation for detection of anomalous origin of a coronary artery from the pulmonary artery (ALCAPA).
Tharakanatha R Yarrabolu +4 more
doaj +1 more source
OBJECTIVES Our goal was to prospectively compare the accuracy of real-time three-dimensional (3D) color Doppler vena contracta (VC) area and two-dimensional (2D) VC diameter in an in vitro model and in the clinical assessment of mitral regurgitation (MR)
S. Little +7 more
semanticscholar +1 more source
The effects of halothane and isoflurane on cardiovascular function in laterally recumbent horses [PDF]
Background. Experimental studies in adult horses have shown that general anaesthesia maintained with isoflurane is associated with less depression of cardiovascular function compared with halothane anaesthesia.
Henley, W +5 more
core +1 more source
ABSTRACT Background Transcatheter patent ductus arteriosus (PDA) device closure is an effective treatment option for premature infants with hemodynamically significant PDA. Left pulmonary artery (LPA) stenosis has been reported as a complication, however there is limited data on risk factors, clinical significance, and long‐term outcomes.
Bryan Mosher +7 more
wiley +1 more source

