Results 201 to 210 of about 34,828 (258)
Some of the next articles are maybe not open access.

Common-mode rejection ratio in current-mode instrumentation amplifiers

Analog Integrated Circuits and Signal Processing, 1995
The current-mode instrumentation amplifier (CMIA) based on op-amp power-supply current sensing offers distinct advantages over conventional architecture designs. The CMIA is studied in detail and the CMRR expression is derived in terms of op-amp and transistor parameters.
W. J. Su, F. J. Lidgey
openaire   +1 more source

Common mode noise rejection in measuring channels

Instruments and Experimental Techniques, 2015
There is a solution proposed in this paper to reject common mode noise (caused by potential difference between a sensor and a measurement channel) in measurement channels. Its main idea is to provide power supply of measuring subsystem using either an accumulator or a capacitor, which is periodically charged from the electric network by switching on ...
Su Jun, Orest Kochan
openaire   +1 more source

Common mode rejection ratio in differential amplifiers

IEEE Transactions on Instrumentation and Measurement, 1991
The common mode rejection ratio (CMRR) of a differential amplifier (DA) using a single operational amplifier and an instrumentation amplifier (IA) using three operational amplifiers is analyzed, and the complete equations are derived for the case when op amps have finite differential and common mode gains.
R. Pallas-Areny, J.G. Webster
openaire   +1 more source

Common-Mode Rejection Ratio-Two Definitions

IEEE Transactions on Biomedical Engineering, 1970
Two different definitions of the common-mode rejection ratio for differential amplifiers are not clearly distinguished. These ratios may differ by orders of magnitude. When differential amplifiers are used to minimize common mode interference in bioelectric measurements, these two ratios should be carefully defined and their magnitudes determined ...
openaire   +2 more sources

Common-mode rejection ratio redefined

IEEE Transactions on Instrumentation and Measurement, 1997
Redefining the common-mode rejection ratio (CMRR), a set of equations is derived for the common-mode gain and the CMRR of differential amplifiers. The results, which are consistent with practice and simulation, show that an amplifier's CMR may exceed the CMR of the active device(s) by intentional unbalancing of the circuit.
openaire   +1 more source

Common-mode rejection of the differential operational amplifier with shunt common-mode feedback

IEEE Journal of Solid-State Circuits, 1975
A simple expression is derived for the common-mode rejection ratio (CMRR) of the differential operational amplifier with shunt common-mode (CM) feedback. The CMRR is exclusively expressed in terms of a fractional unbalance of the bridge circuit composed of an input resistor pair and a shunt CM feedback resistor pair.
T. Furukawa, J. Arisawa
openaire   +1 more source

An ECG/EEG Common Mode Rejection Ratio Analyzer

Journal of Clinical Engineering, 1982
An ECG/EEG common-mode rejection ratio analyzer is discussed and its method of operation is analyzed. In addition to easily performed common-mode rejection ratio tests, this instrument also can perform linearity, frequency response and sweep-speed tests.
openaire   +2 more sources

Novel microwave balanced bandpass filter with high common mode rejection ratio and wide rejection band under common mode operation

Journal of Electromagnetic Waves and Applications, 2019
In this work, a new balanced band pass filter and its design procedure are proposed. The filter is based on a novel resonator, named LTLC resonator, which consists of two inductors (L), two Transmi...
Jose-Luis Olvera-Cervantes   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy