Commutation Failure Mitigation Method Based on Imaginary Commutation Process

open access: yesJournal of Modern Power Systems and Clean Energy, 2022
The commutation failure (CF) mitigation effectiveness is normally restricted by the delay of extinction angle (EA) measurement or the errors of existing prediction methods for EA or firing angle (FA). For this purpose, this paper proposes a CF mitigation
Renlong Zhu   +6 more
doaj   +1 more source

Harmonic elimination of a fifteen‐level inverter with reduced number of switches using genetic algorithm

open access: yesIET Power Electronics, EarlyView., 2023
This article presents a Fifteen‐level inverter topology that has a lesser number of switches (12) and can accommodate isolated DC sources. The total harmonic elimination (THD) of the proposed topology using genetic algorithm is within the IEEE 519 standards. Further, the fifteen‐level inverter is implemented in Hardware and firing pulses were generated
Yogesh Joshi   +4 more
wiley   +1 more source

A Quantitative Index to Evaluate the Commutation Failure Probability of LCC-HVDC with a Synchronous Condenser

open access: yesApplied Sciences, 2019
Since thyristor cannot turn off automatically, line commutated converter based high voltage direct current (LCC-HVDC) will inevitably fail to commutate and therefore auxiliary controls or voltage control devices are needed to improve the commutation ...
Jiangbo Sha   +3 more
doaj   +1 more source

Studies of commutation failures in hybrid LCC/MMC HVDC systems

open access: yesGlobal Energy Interconnection, 2020
A hybrid of line commutated converters (LCCs) and modular multi-level converters (MMCs) can provide the advantages of both the technologies. However, the commutation failure still exists if the LCC operates as an inverter in a hybrid LCC/MMC system.
Gen Li   +6 more
doaj   +1 more source

Influence of single-phase circuit breaker tripping on inverter commutation

open access: yes电力工程技术, 2022
If commutation failure does not occur when single-phase high resistance grounded in single-circuit AC line of inverter,then single-phase circuit breaker tripping may lead to commutation failure.
SONG Xinfu   +4 more
doaj   +1 more source

Commutation failure caused by AC filter switching In HVDC system

open access: yesThe Journal of Engineering, 2019
Switching AC filter may cause harmonic impact, which may lead to commutation failure of HVDC system. Here, the commutation failure mechanism of HVDC system caused by AC filter switching is studied.
Meng Liu   +3 more
doaj   +1 more source

A cascaded H-bridge BLDC drive incorporating battery management [PDF]

open access: yes, 2007
A multilevel BLDC drive is proposed using cascaded H-bridges with isolated sources to provide superior output waveforms and reduced current ripple whilst incorporating observer based SoC estimation.
Bingham, Chris   +3 more
core   +1 more source

Criterion of single-phase fault nature of AC line considering the influence of commutation failure

open access: yes电力工程技术, 2022
The amplitude of AC line current at the inverter side is affected by DC commutation failure and fluctuates for a short time after single-phase trip.The fluctuation range increases with the increase of the number of DC commutation failures,resulting in ...
LI Fengting   +4 more
doaj   +1 more source

Research on commutation failure of Jinsu DC transmission project caused by a complex AC fault

open access: yesThe Journal of Engineering, 2019
Commutation failure is an important factor on safe and stable operation of the receiving-end power grid for high voltage direct current (HVDC) project. A commutation failure event in Jinsu DC transmission project caused by a complex AC failure was taken ...
Wei Peng   +3 more
doaj   +1 more source

A Suppression Strategy for Subsequent Commutation Failures Considering Commutation Capability of Recovery Process

open access: yesShanghai Jiaotong Daxue xuebao, 2022
In order to suppress subsequent commutation failures of high voltage direct current (HVDC), the dynamic process of electrical and control quantities during system recovery is studied, and the main reason for subsequent commutation failures is proposed in
CONG Xinpeng, ZHENG Xiaodong, CAO Yaqian, TAI Nengling, MIAO Yuancheng, LI Ke
doaj   +1 more source