Partial discharge behavior under operational and anomalous conditions in HVDC systems [PDF]
Power cables undergo various types of overstressing conditions during their operation that influence the integrity of their insulation systems. This causes accelerated ageing and might lead to their premature failure in severe cases.
Azizian Fard, M. +3 more
core +3 more sources
A Commutation Failure Prediction and Mitigation Method
The mitigation of commutation failure (CF) depends on the accuracy of CF prediction. In terms of the large error of the existing extinction angle (EA) calculation during the fault transient period, a method for CF prediction and mitigation is proposed. Variations in both DC current and overlap angle (OA) are considered in the proposed method to predict
Renlong Zhu +4 more
openaire +2 more sources
When the large-scale wind power is sent out through the high voltage direct current (HVDC) transmission system and a DC commutation failure occurs, the voltage of AC bus at the sending end decreases first and then increases.
Wei Li +6 more
doaj +1 more source
Mitigating commutation failures in HVDC systems with SFCL deployment
Commutation failures represent a prevalent issue encountered in line-commutated-converter high voltage direct current (LCC-HVDC) systems. As the widespread deployment of HVDC systems continues, the risk associated with commutation failures increases, posing a growing threat to power grids due to their potential to trigger severe consequences, including
Qihuan Dong +5 more
openaire +4 more sources
Since thyristor cannot turn off automatically, line commutated converter based high voltage direct current (LCC-HVDC) will inevitably fail to commutate and therefore auxiliary controls or voltage control devices are needed to improve the commutation ...
Jiangbo Sha +3 more
doaj +1 more source
Integration of a failure monitoring within a hybrid dynamic simulation environment [PDF]
The complexity and the size of the industrial chemical processes induce the monitoring of a growing number of process variables. Their knowledge is generally based on the measurements of system variables and on the physico-chemical models of the process.
Alur +31 more
core +2 more sources
Commutation failure caused by AC filter switching In HVDC system
Switching AC filter may cause harmonic impact, which may lead to commutation failure of HVDC system. Here, the commutation failure mechanism of HVDC system caused by AC filter switching is studied.
Meng Liu +3 more
doaj +1 more source
The failure of the uncountable non-commutative Specker Phenomenon [PDF]
Higman proved in 1952 that every free group is non-commutatively slender, this is to say that if G is a free group and h is a homomorphism from the countable complete free product (X_omega Z) to G, then there exists a finite subset F of omega and a homomorphism h:*_{i in F} Z --> G such that h=h rho_F, where rho_F is the natural map from (X_{i in ...
Shelah, Saharon, Strüngmann, Lutz
openaire +2 more sources
Criterion of single-phase fault nature of AC line considering the influence of commutation failure
The amplitude of AC line current at the inverter side is affected by DC commutation failure and fluctuates for a short time after single-phase trip.The fluctuation range increases with the increase of the number of DC commutation failures,resulting in ...
LI Fengting +4 more
doaj +1 more source