Results 121 to 130 of about 8,022,362 (339)
Parametric stiffness analysis of the Orthoglide [PDF]
This paper presents a parametric stiffness analysis of the Orthoglide. A compliant modeling and a symbolic expression of the stiffness matrix are conducted.
Chablat, Damien +3 more
core +4 more sources
Autonomous deployment and shape reconfiguration of structures is a crucial field of research in space exploration with emerging applications in the automotive, building and biomedical industries.
Chen, Tian, Shea, Kristina
core +1 more source
Remote Monitoring in Myasthenia Gravis: Exploring Symptom Variability
ABSTRACT Background Myasthenia gravis (MG) is a rare, autoimmune disorder characterized by fluctuating muscle weakness and potential life‐threatening crises. While continuous specialized care is essential, access barriers often delay timely interventions. To address this, we developed MyaLink, a telemedical platform for MG patients.
Maike Stein +13 more
wiley +1 more source
Design of 3D-Printed Titanium Compliant Mechanisms [PDF]
This paper describes 3D-printed titanium compliant mechanisms for aerospace applications. It is meant as a primer to help engineers design compliant, multi-axis, printed parts that exhibit high performance.
Howell, Larry L. +2 more
core +1 more source
A compliant-mechanism-based lockable prismatic joint for high-load morphing structures
Yinjun Zhao +4 more
semanticscholar +1 more source
Analytical compliance model is vital to the flexure- based compliant mechanism in its mechanical design and motion control. The matrix is a common and effective approach in the compliance modeling while it is not well developed for the closed-loop serial
Liping Wang, Yao Jiang, Tiemin Li
semanticscholar +1 more source
ABSTRACT Background SOX1 antibody‐positive paraneoplastic neurological syndromes (PNS) exhibit significant population‐specific clinical heterogeneity. While Western cohorts predominantly manifest Lambert‐Eaton myasthenic syndrome (65%–80%), comprehensive clinical characterization and treatment response data in Asian populations remain critically ...
Jin‐Long Ye +11 more
wiley +1 more source
2.5-mm articulated endoluminal forceps using a compliant mechanism. [PDF]
Osawa K +6 more
europepmc +1 more source
Analysis and experimental evaluation of a Stewart platform-based force/torque sensor [PDF]
The kinematic analysis and experimentation of a force/torque sensor whose design is based on the mechanism of the Stewart Platform are discussed. Besides being used for measurement of forces/torques, the sensor also serves as a compliant platform which ...
Antrazi, Sami S., Nguyen, Charles C.
core +1 more source
Pseudo rigid body model for a nonlinear folding compliant mechanism
Brianne Hargrove +3 more
semanticscholar +1 more source

