Results 141 to 150 of about 6,001,301 (391)

The edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley   +4 more
wiley   +1 more source

POSTOPERATIVE LUNG COMPLICATIONS [PDF]

open access: green, 1922
Isabella C. Herb
openalex   +1 more source

Surgical complications in human orthotopic liver transplantation. [PDF]

open access: yes, 1987
Between March 1, 1980 and December 31, 1984, 393 orthotopic liver transplantations (OLT) were performed in 313 consecutive recipients. Technical complications were responsible for a substantial morbidity (41/393 allograft loss--10.4%) and mortality (26 ...
Gordon, RD   +3 more
core  

Producing high quality cranial SRS plans with 4Pi planning technique in a commercial clinical solution

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To generate high‐quality stereotactic radiosurgery (SRS) plans for single cranial lesions using 4Pi planning technique and compare these to our clinical “status quo” plans. Methods Eighteen vestibular schwannoma (VS) patients previously planned with Varian Eclipse RapidArc and treated on a Varian TrueBeam using 6FFF MV photon beams ...
Ganesh Narayanasamy   +4 more
wiley   +1 more source

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Dietary Choline Deprivation Exacerbates Kidney Injury in Streptozotocin-Induced Diabetes in Adult Rats

open access: yesDiabetology
Background: Choline (Ch) deprivation causes kidney injury and dysfunction, and diabetic nephropathy is also known to be a complication of diabetes; thus, this interplay could potentially aggravate diabetic kidney disease.
Ahmed W. Al-Humadi   +6 more
doaj   +1 more source

AAPM medical physics practice guideline 13.a: HDR brachytherapy, part B

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The goal of this report is to assist the clinical medical physicist in assuring that key quality standards and practice considerations are met to ensure safe, reliable, and reproducible high dose rate (HDR) brachytherapy (BT) treatment. This guideline has been developed to provide appropriate minimum standards for such services.
Susan L. Richardson   +8 more
wiley   +1 more source

An inquiry into the incidence of cross-infections, complications and return cases in scarlet fever [PDF]

open access: bronze, 1947
D. G. ff. Edward   +3 more
openalex   +1 more source

Home - About - Disclaimer - Privacy