Results 11 to 20 of about 73,024 (301)
Study on behavior of waffle-type UHPC-GFRP composite slab under three-point loading
The concrete in tension zone of traditional reinforced concrete bridge deck is liable to crack under vehicle loading, leading to easy corrosion of the internal steel rebars and earlier appearance of bridgevvv disease.
Kun Pang +6 more
doaj +1 more source
An experimental study with many variables was carried out to investigate the effective width of simply supported composite beams (T and L sec. beams) with and without slab opening.
Magdy Khalaf +3 more
doaj +1 more source
Ultimate behaviour of composite floor slabs at ambient and elevated temperature [PDF]
This paper is concerned with the ultimate behaviour of composite floor slabs under extreme loading situations resembling those occurring during severe building fires.
Cashell, K, Elghazouli, AY, Izzuddin, BA
core +4 more sources
The composite slab with steel trusses is composed of precast bottom plate and cast-in-place concrete. In engineering applications, cracks often appear in the bottom plate before casting the upper concrete, which even leads to the failure of the composite
Xiuying Yang +3 more
doaj +1 more source
Structural response of interlocking composite masonry slab. [PDF]
This study introduces a semi-fabricated composite floor slab system that consists of a precast inverted ribbed ferrocement panel interlocked in situ with a brick–rib layer to form a composite slab.
Jaafar, Mohd Saleh +3 more
core +1 more source
Cross-laminated timber (CLT) slabs in residential buildings need additional weight, e.g., in the form of screeds or gravel layers, to fulfill the criterion for the highest impact-sound class.
Eva Binder +2 more
doaj +1 more source
A three-dimensional refined numerical simulation model of corrugated steel-concrete slab composite structure under contact explosion load was established by using FEM-SPH coupling method to explore the anti-explosion performance of corrugated steel ...
Kelei Cao +7 more
doaj +1 more source
The finite element analysis model of unbonded prestressed concrete two-way slab supported by four sides and columns was established by using ABAQUS finite element software.
Xiaodong Wang, Shuyu Huang, Miao Wang
doaj +1 more source
The Design of a semi-prefabricated LVL-concrete composite floor [PDF]
This paper describes the design of a novel semi-prefabricated LVL-concrete composite floor that has been developed in New Zealand. In this solution, the floor units made from LVL joists and plywood are prefabricated in the factory and transported to the ...
Fragiacomo, Massimo, Yeoh, David
core +3 more sources
Determination of composite slab strength using a new elemental test method [PDF]
Composite slabs utilizing cold-formed profiled steel decks are commonly used for floor systems in steel framed buildings. The behavior and strength of composite slabs are normally controlled by the horizontal shear bond between the steel deck and the ...
Abdullah, Redzuan, Easterling, W. Samuel
core +1 more source