Could Spinal Cord-Canal Mismatch Compromise Clinical Success of Cervical Disc Replacement in Cervical Myelopathy? [PDF]
Wang Z, Iyer S.
europepmc +1 more source
A two‐dimensional multiscale finite element analysis framework was established for the first‐generation MoSiBTiC alloy, and the mechanical and fracture‐related parameters of the constituent phases were calibrated through experiments and simulations. The framework provides a basis for analyzing crack propagation behavior in its complex microstructure ...
Junfeng Du +4 more
wiley +1 more source
Association of localized circumferential elastic compression with short-term recanalization and safety during urokinase thrombolysis for lower extremity deep vein thrombosis. [PDF]
Zhang Y, Chen H, Han B, Ma Q.
europepmc +1 more source
The temperature dependence of fatigue behavior in nickel‐based superalloys is investigated through high‐resolution measurements of plastic localization. While increasing temperature reduces localization and enhances fatigue performance in René 88DT, Inconel 718 exhibits a sharp degradation at intermediate temperature due to intensified slip ...
M. Calvat +5 more
wiley +1 more source
Glymphatic system bridges peripheral and central nervous system changes in classic trigeminal neuralgia. [PDF]
Jiang J +13 more
europepmc +1 more source
Fatigue Crack Initiation and Growth in Nanocrystalline Ni at Multiple Length‐Scales
Overview of miniaturized in situ SEM fatigue setup and resultant fatigue crack growth data for nanocrystalline Ni. The presented study focuses on the analysis of fatigue crack growth rate (FCGR) in focused ion beam‐notched microcantilevers prepared from nanocrystalline (NC) Ni as a model material.
Igor Moravcik +7 more
wiley +1 more source
Cardiac Dysphagia: When the Heart Disrupts Swallowing. [PDF]
Margol C +4 more
europepmc +1 more source
Tailoring Functional Properties of Ti–Ni–Cu Shape Memory Alloy Thin Films for MEMS Actuators
A comprehensive study of critical parameters required to develop well‐performing Ti–Ni–Cu thin film shape memory alloy microactuators is provided. Materials science and device integration aspects are integrated by addressing structural and physical relationships using complementary characterization techniques as well as a practical fabrication solution
Elaheh Akbarnejad +6 more
wiley +1 more source
Flexor Tendon Sheath Ganglion Causing Concurrent Trigger Wrist and Carpal Tunnel Syndrome. [PDF]
Alsharif M +7 more
europepmc +1 more source
A Lightweight Procedural Layer for Hybrid Experimental–Computational Workflows in Materials Science
We unveil a prototype hybrid‐workflow framework that fuses automatedcomputation with hands‐on experiments. Built atop pyiron, a lightweight, parameterized layer translates procedure descriptions into executable manual steps, syncing instrument settings, human interventions, and data capture in real‐time today.
Steffen Brinckmann +8 more
wiley +1 more source

