Results 171 to 180 of about 727,683 (238)
Some of the next articles are maybe not open access.

Development of a two-layer dense-pixel LYSO Compton camera prototype for prompt gamma imaging

Physics in Medicine and Biology, 2023
Objective. Lutetium–yttrium orthosilicate (LYSO)-based Compton camera (CC) has been proposed for prompt gamma imaging due to its high detection efficiency and position resolution.
Zhiyang Yao   +3 more
semanticscholar   +1 more source

Compton camera imaging

2013 Seventh International Conference on Sensing Technology (ICST), 2013
The goal of the Compton camera imaging is to visualize the gamma-ray intensity map. Here, we focus on the case where the gamma-ray sources are sufficiently far from the camera and propose a new reconstruction method for the Compton camera imaging. The method is called the bin-mode estimation (BME).
Shiro Ikeda   +5 more
openaire   +1 more source

Based on Compton Camera

2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE), 2016
Compton Cameras have been proposed as an alternative to SPECT imaging with Gamma Camera, mainly due to factors such as the electronic collimation, which allows a bigger field of view and provides further information from the acquired events if compared to devices with mechanical collimation.
J. M. Blasco, V. González, E. Sanchis
openaire   +1 more source

Cameras shapes for medical imaging Compton cameras

SPIE Proceedings, 2010
The shape of the detectors that comprise a Compton camera largely determines the geometric distribution of the set of data that is measured. It is our hypothesis that the geometric distribution of a set of data determines the informational contents of the data.
Bruce Smith, L. Joseph Denbina
openaire   +1 more source

A Compton camera for multi-tracer imaging

2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149), 2001
A high-energy resolution Compton camera consisting of two segmented Ge detectors is proposed for multitracer research. The basic parameters affecting its spatial resolution are described. Monte Carlo simulations were performed to optimize the detector system. Its suitability for multitracer technology was demonstrated by a test experiment.
Y.F. Yang   +4 more
openaire   +1 more source

A novel Compton camera with an annular absorber for enhancing the imaging efficiency in regions directly ahead: A simulation study

Journal of Nuclear Science and Technology, 2023
Compton camera is an extremely important technology to observe the prompt emissions from gamma-ray bursts. To improve the imaging efficiency of regions directly ahead of the system, a novel Compton camera with an annular absorber was proposed and ...
Ziquan Yuan   +6 more
semanticscholar   +1 more source

SPEIR: A Ge Compton camera

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
Abstract The SPEctroscopic Imager for γ - Rays (SPEIR) is a Compton scatter γ -ray imaging system of high efficiency and spectroscopic resolution with a 4- π field-of-view. The imaging system consists of double-sided segmented (DSSD) planar Ge detectors, an acquisition system instrumenting the detectors, and a set of data analysis methods.
L. Mihailescu   +4 more
openaire   +1 more source

A new modality of bidimensional Compton camera

2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2015
The concept of Compton camera originates from the need to improve sensitivity in Single Photon Emission Imaging, which uses hole collimators. It advocates electronic collimation which registers radiation emitted by the radiating object and scattered by a scattering detector placed before an absorption detector.
Cebeiro, Javier   +3 more
openaire   +3 more sources

Resolution recovery reconstruction for a Compton camera

Physics in Medicine and Biology, 2013
The spatial resolution from Compton cameras suffers from measurement uncertainties in interaction positions and energies. The degree of degradation in spatial resolution is shift-variant (SV) over the field-of-view (FOV) because the imaging principle is based on the conical surface integration.
Soo Mee, Kim   +7 more
openaire   +2 more sources

Simultaneous Coordinate Maximization Algorithm for Maximum A Posteriori Compton Camera Imaging With Markov Random Field Prior

IEEE Transactions on Instrumentation and Measurement
It is widely acknowledged that maximum a posteriori (MAP) estimation, when combined with a Markov random field (MRF) prior, is an effective tool for Compton camera imaging from Poisson data.
Nhan Le, H. Snoussi, A. Iltis
semanticscholar   +1 more source