Pediatric Phantom Library Constructed From ICRP Mesh-Type Reference Computational Phantoms (MRCPs)
International Commission on Radiological Protection (ICRP) recently developed the adult and pediatric mesh-type reference computational phantoms (MRCPs) in high-quality/fidelity mesh format, featuring high deformability into various body sizes and poses.
Yeon Soo Yeom +2 more
exaly +4 more sources
Impact of Eye and Breast Shielding on Organ Doses During Cervical Spine Radiography: Design and Validation of MIRD Computational Phantom [PDF]
Purpose: The study aimed to design and validate computational phantoms (MIRD) using the MCNPX code to assess the impact of shielding on organ doses.Method: To validate the optimized phantom, the obtained results were compared with experimental results ...
Wiam Elshami +8 more
doaj +2 more sources
Development of anthropomorphic computational phantoms at the UFPE
To evaluate the amount of energy deposited in radiosensitive organs and tissues of the human body, when an anthropomorphic phantom is irradiated, researchers in numerical dosimetry use the so-called exposure computational models (ECMs).
José Wilson Vieira +10 more
doaj +2 more sources
Determination of Exposure during Handling of I Seed Using Thermoluminescent Dosimeter and Monte Carlo Method Based on Computational Phantom [PDF]
Background The thermoluminescent dosimeter (TLD) and Monte Carlo (MC) dosimetry are carried out to determine the occupational dose for personnel in the handling of 125I seed sources.
Hosein Poorbaygi +4 more
doaj +1 more source
Impact of Noise Level on the Accuracy of Automated Measurement of CT Number Linearity on ACR CT and Computational Phantoms [PDF]
Background: Methods for segmentation, i.e., Full-segmentation (FS) and Segmentation-rotation (SR), are proposed for maintaining Computed Tomography (CT) number linearity.
Choirul Anam +6 more
doaj +1 more source
Impact of ROI Size on the Accuracy of Noise Measurement in CT on Computational and ACR Phantoms [PDF]
Background: The effect of region of interest (ROI) size variation on producing accurate noise levels is not yet studied. Objective: This study aimed to evaluate the influence of ROI sizes on the accuracy of noise measurement in computed tomography (CT ...
Choirul Anam +6 more
doaj +1 more source
Fetal Dose Variations in Lung Scintigraphy of Pregnant Woman: The Role of Fetal Body Habitus [PDF]
Introduction: This study aims to address the radiation exposure incurred by lung scintigraphy in pregnant patients suspected of pulmonary embolism and to investigate the dose variations due to different body habitus of the fetus. Material and Methods: In
Motahareh Zohur-Karbaf +2 more
doaj +1 more source
Decision for radiotherapy during the first trimester of pregnancy may occur, as patients may not realize their pregnancy at the very early stage. Since radiation dose can affect fetal development, the aim of this study was to evaluate fetal dose and ...
Pattarakan Suwanbut +4 more
doaj +1 more source
Exposure computational models with voxel phantoms coupled to EGSnrc Monte Carlo code
In computational dosimetry of ionizing radiation, the energy deposited in radiosensitive organs and tissues is evaluated when an anthropomorphic simulator (phantom) is irradiated using Exposure Computational Models (ECMs).
José Wilson Vieira +13 more
doaj +1 more source
In this work, the optimum homogeneous phantom size for an equivalent whole-body electromagnetic (EM) modeling is calculated. This will enable the simple characterization of plane wave EM attenuation and far-field link budgets in Active Medical Implant ...
Iñaki Ortego-Isasa +4 more
doaj +1 more source

