Results 211 to 220 of about 308,543 (305)

Recent Advances of Slip Sensors for Smart Robotics

open access: yesAdvanced Materials Technologies, EarlyView.
This review summarizes recent progress in robotic slip sensors across mechanical, electrical, thermal, optical, magnetic, and acoustic mechanisms, offering a comprehensive reference for the selection of slip sensors in robotic applications. In addition, current challenges and emerging trends are identified to advance the development of robust, adaptive,
Xingyu Zhang   +8 more
wiley   +1 more source

Ubiquitin-conjugating enzyme membrane anchor Cue1 confers resistance to hygromycin B in <i>Saccharomyces cerevisiae</i>. [PDF]

open access: yesMicroPubl Biol
Avaala JA   +7 more
europepmc   +1 more source

Material Selection and Geometric Design for Few‐filament Shape Memory Polymer Yarns for Force Generation

open access: yesAdvanced Materials Technologies, EarlyView.
A custom shape memory polymer material selection process relates quantitative application criteria (e.g., compression garment yarns) to material characterization information. The selected materials are manufactured into yarn geometries, which expand the design space by creating structural stress‐strain profiles beyond the nominal material stress‐strain
Michaela Andrews   +2 more
wiley   +1 more source

Neural network modeling of Lassa fever spread and disability effects. [PDF]

open access: yesSci Rep
Sabir Z   +6 more
europepmc   +1 more source

A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant

open access: yesAdvanced Materials Technologies, EarlyView.
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein   +2 more
wiley   +1 more source

Tunable‐Threshold UV Dosimetry With Programmable Luminescent Tags via Oxygen‐Mediated Room‐Temperature Phosphorescence

open access: yesAdvanced Materials Technologies, EarlyView.
A fully organic UV threshold dosimeter is developed by exploiting the oxygen‐sensitive room‐temperature phosphorescence of a purely organic emitter in a polymer matrix. Upon reaching a specific cumulative UV dose, photochemical oxygen depletion triggers a sharp, high‐contrast emission.
Tim Achenbach   +3 more
wiley   +1 more source

Galinstan Liquid Metal/Polyurethane Composite as a Multifunctional Stretchable Electrode and Piezoresistive Strain Sensor With Minimal Drift

open access: yesAdvanced Materials Technologies, EarlyView.
Liquid metal additives are processed in elastomer host resulting in highly conductive and stretchable composites. The material functions as a piezoresistive sensor with minimal drift, low stiffness, and enhanced operating range. The film can replace wires to charge a mobile phone at ∼350% strain and monitors bodily motion in real‐time via a portable ...
Patryk Wojciak   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy