Results 281 to 290 of about 177,681 (318)
Some of the next articles are maybe not open access.
Cardiovascular Electrophysiology, 2022
Pacing leads with extendable‐retractable helix (EHL) are alternatives to fixed‐helix leads (FHL) for conduction system pacing (CSP), but data on handling characteristics are limited.
E. Tan +7 more
semanticscholar +1 more source
Pacing leads with extendable‐retractable helix (EHL) are alternatives to fixed‐helix leads (FHL) for conduction system pacing (CSP), but data on handling characteristics are limited.
E. Tan +7 more
semanticscholar +1 more source
Cardiovascular Electrophysiology
Left bundle branch area (LBBA) pacing (LBBAP) has been proposed as an alternative therapy option in patients indicated for cardiac pacing to treat bradycardia or heart failure. The aim of the study was to evaluate the safety and effectiveness of LBBAP in
P. Vijayaraman +11 more
semanticscholar +1 more source
Left bundle branch area (LBBA) pacing (LBBAP) has been proposed as an alternative therapy option in patients indicated for cardiac pacing to treat bradycardia or heart failure. The aim of the study was to evaluate the safety and effectiveness of LBBAP in
P. Vijayaraman +11 more
semanticscholar +1 more source
Cardiovascular Electrophysiology
Biventricular pacing (BIV) is the gold standard for cardiac resynchronization therapy (CRT). Thirty percent of patients do not respond to CRT. Conduction system pacing (CSP) represents a viable alternative.
C. Marallo +10 more
semanticscholar +1 more source
Biventricular pacing (BIV) is the gold standard for cardiac resynchronization therapy (CRT). Thirty percent of patients do not respond to CRT. Conduction system pacing (CSP) represents a viable alternative.
C. Marallo +10 more
semanticscholar +1 more source
Pacing and clinical electrophysiology : PACE
Conduction system pacing (CSP) is increasingly utilized to prevent and correct dyssynchrony. Barriers to CSP adoption include limited training, methodologic variability, laboratory slot allocation, and few data on learning curves.
William Marion +4 more
semanticscholar +1 more source
Conduction system pacing (CSP) is increasingly utilized to prevent and correct dyssynchrony. Barriers to CSP adoption include limited training, methodologic variability, laboratory slot allocation, and few data on learning curves.
William Marion +4 more
semanticscholar +1 more source
Journal of interventional cardiac electrophysiology, 2023
A. Parlavecchio +14 more
semanticscholar +1 more source
A. Parlavecchio +14 more
semanticscholar +1 more source
Long-Term Safety and Feasibility of Left Bundle Branch Pacing in a Large Single-Center Study
Circulation: Arrhythmia and Electrophysiology, 2021Shengjie Wu, Lei Xu, Zhou-Qing Huang
exaly
A Soft and Absorbable Temporary Epicardial Pacing Wire
Advanced Materials, 2021Li Ding, Shiyu Cheng, Rui-Hua Dong
exaly

