Results 161 to 170 of about 3,781,470 (370)
Correcting the Bias Correction for the Bootstrap Confidence Interval in Mediation Analysis. [PDF]
Tibbe TD, Montoya AK.
europepmc +1 more source
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab+6 more
wiley +1 more source
Modified likelihood approach for Wald-typed interval of the shape parameter in Weibull distribution
The Weibull distribution, widely used in lifetime analysis, is characterized by its shape parameter. We analytically derived Wald-type confidence intervals using standard and modified profile likelihood methods.
Patchanok Srisuradetchai+2 more
doaj +1 more source
Application of isotonic regression in estimating EDg and its 95% confidence interval by bootstrap method for a biased coin up-and-down sequential dose-finding design. [PDF]
Hemraj C+3 more
europepmc +1 more source
Confidence Intervals for Linear Functions of the Normal Parameters [PDF]
V. M. Joshi
openalex +1 more source
Abstract Purpose To assess the predictive capability of CT radiomics features for early recurrence (ER) of pancreatic ductal adenocarcinoma (PDAC). Methods Postoperative PDAC patients were retrospectively selected, all of whom had undergone preoperative CT imaging and surgery. Both patients with resectable or borderline‐resectable pancreatic cancer met
Xinze Du+7 more
wiley +1 more source
On Fixed Accuracy Confidence Interval in Multivariate Normal Distribution with Order 1 Autoregressive Covariance Structure. [PDF]
Sarkar P+2 more
europepmc +1 more source
Statistics in Medicine: Calculating confidence intervals for survival time analyses [PDF]
David Machin, Martin J. Gardner
openalex +1 more source
Log file‐based quality assurance method for respiratory gating system
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon+7 more
wiley +1 more source
Abstract Purpose An evaluation of the accuracy, safety, and efficiency of the Halcyon ring delivery system (RDS) for stereotactic radiosurgery (SRS) treatment to relatively small (1–3 cm) brain lesions. Methods After completing the extensive in‐house quality assurance checks including Winston–Lutz test and independent dose verification via MD Anderson ...
Kate Hazelwood+5 more
wiley +1 more source