Results 11 to 20 of about 31,070 (270)
This research investigates the nonlinear behavior of scaled infilled masonry (IFM), confined masonry (CM), and reinforced concrete (RC) structures by utilizing and validating two tests from the literature as benchmarks.
Asad Ullah Qazi +4 more
doaj +2 more sources
A new proposal for the design of confined masonry buildings [PDF]
Confined masonry has been efficiently used for buildings in Latin-America, Northern-Africa and Asia, even in seismic areas. However, despite all the research on the seismic behaviour of this structural typology, mainly in Latin-America, the lack of ...
Rui Marques, Paulo B. Lourénço
openalex +3 more sources
Masonry infill walls under blast loading using confined underwater blast wave generators (WBWG) [PDF]
The vulnerability of the masonry envelop under blast loading is considered critical due to the risk of loss of lives. The dynamic behaviour of masonry infill walls subjected to dynamic out-of-plane loading was experimentally investigated in this work ...
Jo�ão M. Pereira +2 more
openalex +3 more sources
Benchmarking The Use of Shaking Table for Simulating the Earthquake Performance of Typical Residential Houses for Disaster Risk Reduction [PDF]
This study presents a review focused on the role of earthquake shaking table simulation in understanding the potential risk of confined masonry structures of residential houses.
Hayati Yulia +3 more
doaj +1 more source
Geopolymer concrete is preferred over OPC due to its use of energy waste such as fly ash, making it more sustainable and energy-efficient. However, limited research has been done on its seismic characterization in confined masonry, highlighting a gap in ...
Muhammad Mubashir Ajmal +6 more
doaj +1 more source
Unreinforced masonry structures are vulnerable to seismic action, especially with window openings. Therefore, a strengthening technique needs to be proposed to improve the seismic performance of the confined masonry walls with window openings.
Guo-an Liu +6 more
doaj +1 more source
Response of masonry systems against blast loading
In this paper eight successive experimental blast tests with an increasing TNT equivalent charge weights ranging from 0.56 kg to 17.78 kg were conducted on unreinforced, ferrocemented overlay masonry and confined masonry walls.
Eid Badshah +3 more
doaj +1 more source
The strength capacity of confined masonry column is one of the topics that need to be studied. In this study, the efficiency of using different types of advanced composite (non-corrosive materials) such as fiber reinforced polymer (FRP), fiber reinforced
Zuhair Al-Jaberi, John J. Myers
doaj +1 more source
The use of Fiber Reinforced Polymer (FRP) materials for the external confinement of existing concrete or masonry members is now an established technical solution.
Khalid Saqer Alotaibi +1 more
doaj +1 more source
Effect of Aftershocks on Seismic Fragilities of Single-Story Masonry Structures
The effect of aftershocks on the fragility of single-story masonry structures is investigated using probabilistic seismic demand analysis Finite element models of an unreinforced masonry (URM) structure and a confined masonry (CM) structure are ...
Hao Zhang +4 more
doaj +1 more source

