Results 221 to 230 of about 283,799 (295)

Dual‐Mode Magnetic Elastomer for On‐Demand Motion and Degradation

open access: yesAdvanced Functional Materials, EarlyView.
A dual‐mode magnetic elastomer is introduced, enabling DC field‐driven programmable actuation and AC field‐driven magnetothermal degradation. GHz‐range magnetic fields generate ultrafast heating of magnetic nanoparticles that activates cleavage of the silicone elastomer matrix.
Jieun Han   +13 more
wiley   +1 more source

N-nitrosaccharins are not insensitive chemicals. [PDF]

open access: yesNat Commun
Muravyev NV   +3 more
europepmc   +1 more source

Titanium Suboxides Responsible for Electronic Anomaly Near Room Temperature in the Ti3C2Tx MXene

open access: yesAdvanced Functional Materials, EarlyView.
Our multi‐technique study reveals that the near‐room‐temperature anomaly in Ti3C2Tx MXene is linked to titanium suboxide nanodomains, including Ti3O5, embedded within the MXene host. Their temperature‐driven transformation provides an alternative explanation to solvent‐ and swelling‐based models and offers new insight into the thermally activated ...
Bence G. Márkus   +8 more
wiley   +1 more source

Aqueous Two‐Phase Bioinks for Discrete Packing and Compartmentalization of 3D Bioprinted Cells

open access: yesAdvanced Healthcare Materials, EarlyView.
Aqueous two‐phase systems (ATPS) enable the formation of biomimetic interfaces crucial for tissue engineering. However, clinical translation remains limited by the challenge of precisely controlling cellular compartmentalization. Here, we developed ATPS biomaterial inks for 3D bioprinting allowing tuneable droplet formation via NaCl modulation.
Martina Marcotulli   +17 more
wiley   +1 more source

An Edible H2O2 Biosensor for Gastrointestinal Metabolites and Peroxidase Enzyme Quantification

open access: yesAdvanced Healthcare Materials, EarlyView.
We present an edible biosensor for gastric fluid analysis that integrates a caffeic acid–horseradish peroxidase redox system into an edible electrolyte‐gated transistor. The device enables rapid, low‐volume detection of H2O2 and, with minimal modification, metabolites and enzyme activity in simulated gastrointestinal conditions.
Valerio Francesco Annese   +10 more
wiley   +1 more source

Fluid Forces Control Structural Remodeling of Blind‐Ended Lymphatic Microvessels

open access: yesAdvanced Healthcare Materials, EarlyView.
Using innovative microfluidic biofabrication with fluid mechanical insights, we recapitulated the blind‐ended microanatomy and physiological drainage properties of capillary lymphatics. Our results reveal the interrelationship between intra‐ and extraluminal regions of lymphatic vessels due to flow‐induced sprouting and morphological changes that ...
Jacob C. Holter   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy