Modeling and Design of a Soft Capacitive Slip Sensor with Fluid Dielectric Interlayer. [PDF]
Landi E +5 more
europepmc +1 more source
This comprehensive review presents a progressive roadmap for perovskite vision detectors. Centered on perovskite‐based artificial perception, the graphic illustrates a systematic evolution: starting with fundamental material engineering and device architectures, advancing toward complex functional strategies such as flexible neuromorphic imaging ...
Chenglong Li +14 more
wiley +1 more source
End-to-end hardware modeling and sensitivity optimization of photoacoustic signal readout chains. [PDF]
Yang W +5 more
europepmc +1 more source
Anisotropy Factor Spectra for Weakly Allowed Electronic Transitions in Chiral Ketones
Anisotropy factor spectra for the weak n→π*‐type A‐band of chiral ketones cannot be described within the Franck–Condon approximation. Thus, we present such spectra computed by accounting for Herzberg–Teller corrections and compare them to experiments for fenchone, camphor and 3MCP to describe chiroptical properties of these molecules in the mid to near
Leon A. Kerber +5 more
wiley +1 more source
Circular MIMO antenna with ML-based bandwidth and isolation prediction for 6G communications. [PDF]
Alam MM +7 more
europepmc +1 more source
Subthreshold Time‐Mode All‐Digital DLL With Built‐In Linearization
This paper presents a subthreshold time‐mode all‐digital delay‐locked loop (DLL) for low‐frequency clock generation. The large and tunable delay of the DLL is obtained using a static inverter delay line whose supply voltage is in the vicinity of 100 mV and adjustable by varying supply voltage. Phase error is processed by a time‐mode proportional block (
Fei Yuan, Wenhao Wu, Yushi Zhou
wiley +1 more source
Spatiotemporal Encoding With Nonlinear Gradient Hardware Using Pulseq: From Principles to Practical Demonstration. [PDF]
Holl A +8 more
europepmc +1 more source
An Ultra‐Low‐Power Biopotential Acquisition Analog Front‐End Chip for Wearable Devices
A 0.8‐V, 1.2‐μW biopotential AFE combines a chopper‐stabilized CCIA with dual‐time‐scale EDO management. The slow DSL preserves > 1 GΩ input impedance, whereas an event‐triggered fast‐recovery path shortens return to the linear range after abrupt electrode‐offset disturbances. ABSTRACT A 0.8‐V, 1.2‐μW biopotential analog front‐end (AFE) IC is presented
Zhang Xin +4 more
wiley +1 more source
Ultrabroadband 1D and 2D NMR Spectroscopy. [PDF]
Woordes YT +11 more
europepmc +1 more source
Flexible Direct‐Conversion X‐Ray Detectors: From Emerging Materials to Conformal Imaging
This comprehensive review analyzed the performance, challenges, and future directions of four emerging material systems for next‐generation flexible direct‐conversion X‐ray detectors: organic semiconductors, perovskites, metal–organic frameworks, and inorganic metal compounds.
Haipeng Di +11 more
wiley +1 more source

