Inter‐Individual Differences in T1, T2, and Proton Density Using Quantitative Synthetic Imaging for 1H‐MRS Quantification

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Metabolite concentrations can be determined from proton magnetic resonance spectroscopy (1H‐MRS) data using water as an internal reference. This calculation requires tissue‐specific water T1 and T2 relaxation constants and proton density (PD).
Samantha A. Leech   +4 more
wiley   +1 more source

Spatial Image Gradient Estimation From the Diffusion MRI Profile

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose In the course of diffusion, water molecules encounter varying values for the relaxation‐time properties of the underlying tissue. This factor, which has rarely been accounted for in diffusion MRI (dMRI), is modeled in this work, allowing for the estimation of the gradient of relaxation‐time properties from the dMRI signal. Methods With
Iman Aganj   +4 more
wiley   +1 more source

Surface distributed acoustic sensing for mineral exploration. [PDF]

open access: yesSci Rep
Gyger L   +4 more
europepmc   +1 more source

Effects and Correction of Patient Bulk Motion in Cranial DENSE MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Applications of DENSE to measure cardiac driven brain tissue pulsations are highly sensitive to bulk patient motion due to the sub‐millimeter displacement encoding required, limiting its accuracy, reproducibility, and use in pediatric and aging populations.
Caroline A. Doctor   +4 more
wiley   +1 more source

Quantitative Comparison of Multi‐Echo Spin Echo and Multi‐Echo Gradient Echo Myelin Water Imaging in a Panel of Mbp Enhancer‐Edited Mouse Lines

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate the correspondence between myelin water fraction (MWF) estimates derived from multi‐echo spin echo (MESE) and multi‐echo gradient echo (MGRE) imaging in fixed mouse brain tissue, using a panel of myelin basic protein (Mbp) enhancer‐edited mouse lines exhibiting graded hypomyelination.
Vladimir Grouza   +11 more
wiley   +1 more source

Spatiotemporal Encoding With Nonlinear Gradient Hardware Using Pulseq: From Principles to Practical Demonstration

open access: yesMagnetic Resonance in Medicine, EarlyView.
Purpose Provide the theoretical foundation and the first practical demonstration of spatiotemporal encoding (SPEN) using additional nonlinear gradient hardware. Methods The quadratic phase profile can be generated either by a chirped‐RF pulse combined with a constant gradient or, directly, by a quadratic gradient pulse.
Andreas Holl   +8 more