Results 201 to 210 of about 3,794,115 (259)

The "16-gram window" of contact-force: A new criterion for very high-power short-duration ablation. [PDF]

open access: yesJ Arrhythm
Bismpos D   +9 more
europepmc   +1 more source

Advances in Sustainable and Wearable Textile Based Soft Robotics

open access: yesAdvanced Functional Materials, EarlyView.
This Review examines advances in wearable textile‐based soft robotics, focusing on sustainable materials, integrated sensing, and scalable actuation. It discusses manufacturing and system integration across healthcare, assistive robotics, prosthetics, and human–machine interfaces, and highlights key challenges in circular design, including life‐cycle ...
Zahir Abbas   +6 more
wiley   +1 more source

A Data-Driven Approach to Estimate Changes in Peak Knee Contact Force With Exoskeleton Assistance. [PDF]

open access: yesIEEE Trans Neural Syst Rehabil Eng
Miller DE   +4 more
europepmc   +1 more source

Structure‐Guided Dynamical Mechanics in Bioinspired Double Twisted Laminated Thin Films

open access: yesAdvanced Functional Materials, EarlyView.
This work explores a dynamic mechanistic study of crack propagation and puncture testing via real‐time monitoring of crack initiation, propagation, and termination through nature‐inspired single and double twisted architectures fabricated from cellulose nanocrystals.
Justin Brackenridge   +4 more
wiley   +1 more source

Optical Signature of Moiré Superlattices Formed by Twisted SrTiO3 Membranes

open access: yesAdvanced Functional Materials, EarlyView.
We discover optical signatures from bonded interfaces in twisted SrTiO3 moiré superlattices, including low‐frequency Raman vibrational modes and strong second‐harmonic generation, consistent with strong interlayer coupling inferred from cross‐sectional electron microscopy and ab initio calculations. ABSTRACT Moiré superlattices formed at the interfaces
T. A. M. Ragib Shahriar   +13 more
wiley   +1 more source

Femoroacetabular Contact Force Measurement in Hip Arthroscopy: Surgical Technique. [PDF]

open access: yesArthrosc Tech
Dantas P   +6 more
europepmc   +1 more source

Electrospun Wood‐Derived Biopolymers as Electrodes in Electrochemical Energy Storage Technologies

open access: yesAdvanced Functional Materials, EarlyView.
Electrospinning transforms wood‐derived cellulose and lignin into architecturally defined, binder‐free carbon electrodes with tuneable porosity and functionality. This review shows how fibre design enables decoupled charge and mass transport, enhancing performance across battery systems, while identifying key challenges in spinnability, scalability ...
Michael W. Thielke   +3 more
wiley   +1 more source

Embedded Ferroelectric Nanoclusters Can Drive Polarization Reversal in a Non‐Ferroelectric Polar Film via the Proximity Effect

open access: yesAdvanced Functional Materials, EarlyView.
Ferroelectric nanoclusters create local internal fields in a normally non‐switchable polar film because of polarization mismatch at their interfaces. That field opposes polarization in the regions with larger polarization and reinforces polarization in the regions with smaller polarization.
Anna N. Morozovska   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy