Results 111 to 120 of about 2,575,850 (359)
The characteristics of a vertical n–p–i–p heterostructure transistor device, which exhibits a voltage‐tunable transition between Gaussian and sigmoid functions, are investigated. The mixed state of the transfer curve enables the utilization of both exploitation and exploration, improving computational performance in reinforcement learning tasks ...
Jisoo Park+7 more
wiley +1 more source
2D Borophene: In‐Plane Hyperbolic Polaritons in the Visible Spectral Range
Researchers have synthesized the χ3 phase of borophene, a 2D metal, using chemical vapor deposition. Combining theory and deep‐subwavelength spectroscopy, they uncover borophene's unique anisotropic optical behavior in the visible range. This breakthrough paves the way for advanced optoelectronic devices using borophene‐based heterostructures ...
Yaser Abdi+5 more
wiley +1 more source
Design and Applications of Multi‐Frequency Programmable Metamaterials for Adaptive Stealth
This article provides a comprehensive overview of metamaterials, including their fundamental principles, properties, synthesis techniques, and applications in stealth, as well as their challenges and future prospects. It covers topics that are more advanced than those typically discussed in existing review articles, while still being closely connected ...
Jonathan Tersur Orasugh+4 more
wiley +1 more source
Bio‐based and (semi‐)synthetic zwitterion‐modified novel materials and fully synthetic next‐generation alternatives show the importance of material design for different biomedical applications. The zwitterionic character affects the physiochemical behavior of the material and deepens the understanding of chemical interaction mechanisms within the ...
Theresa M. Lutz+3 more
wiley +1 more source
Preliminary Observations of Soft (Hydrophilic) Contact Lenses [Abridged] [PDF]
Montague Ruben
openalex +1 more source
Epitaxial piezoelectric α‐quartz/Si BioNEMS sensors, made using soft chemistry, effectively detect the Chikungunya virus. They have a mass sensitivity of 205 pg Hz−1 in liquid and can detect the virus at a limit of 9 ng mL−1. This development enables high‐frequency mass devices for point‐of‐care testing in healthcare and other electronic applications ...
Raissa Rathar+12 more
wiley +1 more source
RISK FACTORS FOR CONTACT LENS COMPLICATIONS
Contact lenses are freely available without professional examination and fitting, as well as without adequate introduction and instructions on handling, disinfection and storage. Contact lenses may have physiological, metabolic and anatomic effect on the
Mirna Štabuc Šilih
doaj