Results 71 to 80 of about 35,894 (264)

From Food to Power: Hydrogel Thermoelectrics for Ingestible Electronics

open access: yesAdvanced Functional Materials, EarlyView.
We introduce a fully edible thermoelectric–electrochromic platform that harvests heat from food and converts it into a visible color change. N‐type and p‐type hydrogel thermoelectric generators connected in series power anthocyanin‐based electrochromic displays, demonstrating the feasibility of safe, biodegradable, ingestible systems for on‐food ...
Antonia Georgopoulou   +3 more
wiley   +1 more source

Strain‐Programmable Luminescent Adhesive Patch With Tartrazine‐Mediated Optical Skin Clearing for Photochemical Tissue Bonding

open access: yesAdvanced Functional Materials, EarlyView.
We propose a suture‐complementary approach that integrates optical skin clearing with a strain‐programmable luminescent adhesive patch. Hyaluronic acid promotes transdermal delivery of tartrazine to improve optical clearing and stabilizes its interaction with a photosensitizer. Optical clearing increases the penetration depth of visible light into skin,
Seong‐Jong Kim   +6 more
wiley   +1 more source

ON THE CONTINUOUS CASTING OF ALUMINIUM

open access: yesJournal of Japan Institute of Light Metals, 1955
With a semi-continuous and continuous ingot casting apparatus of a very small scale (the diameter of ingots is 43mm or 47mm), the authors carried out some experiments to know how the casting conditions affect on the structure, the density and the grain size of the ingots.The apparatus we used was shown in Fig. 1.
KODA, SHIGEYASU   +2 more
openaire   +2 more sources

Mechanical Behavior and Fracture Mechanisms of MXene/PVDF Nanocomponsites: In Situ Characterization and Multiscale Analysis

open access: yesAdvanced Functional Materials, EarlyView.
Multiscale experiments and modeling reveal how Ti3C2Tx MXene nanosheets reinforce PVDF nanocomposites. An optimal MXene loading (∼1 wt.%) nearly doubles tensile strength through efficient stress transfer, flake alignment, and crack‐deflection mechanisms, transforming ductile polymer behavior into a controlled multi‐stage fracture pathway which aligns ...
Bita Soltan Mohammadlou   +5 more
wiley   +1 more source

Continuous roll casting of aluminium alloys – casting parameters analysis [PDF]

open access: yesMetalurgija, 2010
The main goal of the paper was to present the influence of casting parameters on casting conditions and interference of casting parameters on the final strip characteristics such as constant strip thickness, surface quality and roughness of aluminum ...
E. Krstić Vukelja   +2 more
doaj  

Receptor‐Free Identification of Toxic Gases Enabled by Hygroscopic Aqueous Salt Films

open access: yesAdvanced Functional Materials, EarlyView.
Water as a gas sensor coating sounds impossible—until it stops evaporating. Here, hygroscopic salt solutions (LiCl, LiBr, H3PO4) form non‐drying aqueous films on CNT chemiresistors under ambient air. Gases partition into these liquid layers, sometimes transforming into water, and generate salt‐specific resistance fingerprints across a four‐channel ...
Seongwoo Lee   +5 more
wiley   +1 more source

Solidification microstructure of M2 high speed steel by different casting technologies [PDF]

open access: yesChina Foundry, 2011
The present work investigated the solidification microstructure of AISI M2 high speed steel manufactured by different casting technologies, namely iron mould casting and continuous casting. The results revealed that the as-cast structure of the steel was
Zhou Xuefeng, Fang Feng, Jiang Jianjing
doaj  

Regulated Ion‐Diffusion Hydrogels for Subtle and Multimodal Temperature‐Strain Sensing in Wound Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang   +7 more
wiley   +1 more source

Process Practice of Increasing the Number of 410S  Stainless Steel Continuous Casting Furnace

open access: yesTeshugang, 2019
In the process of producing 410S stainless steel by Xinggang one-step method ( dephosphorization station + 60 t AOD + LF) , the tap-to-tap cycle of AOD is much larger than that of continuous casting machine pouring and dephosphorization station and the ...
李广斌   +5 more
doaj  

Multimodal Soft Surgical Robots Enabled by Eco‐Degradable, Sterilizable Polymers and Transient Electronics

open access: yesAdvanced Functional Materials, EarlyView.
A compostable PGS soft surgical robot with interchangeable modules integrates transient Mo tactile and Si thermal sensors for dual feedback. The device preserves its function after clinical‐grade sterilization, demonstrates stable actuation and cardiac tissue grasping with real‐time in vivo pulsatile monitoring, and biodegrades post‐use with soil‐safe, 
Minseong Chae   +27 more
wiley   +1 more source

Home - About - Disclaimer - Privacy