Results 71 to 80 of about 1,823,293 (168)
A long‐term monitoring system for Alzheimer's disease is developed using fluorescently labeled inverse opal hydrogel with an intraocular lens. The permeability and inherent photonic properties of inverse opal hydrogel facilitate the cumulative enhancement of the fluorescence signal.
Hyo Lee +8 more
wiley +1 more source
Abstract Background To compare results from different corneal astigmatism measurement instruments; to reconstruct corneal astigmatism from the postimplantation spectacle refraction and toric intraocular lens (IOL) power; and to derive models for mapping measured corneal astigmatism to reconstructed corneal astigmatism.
Achim Langenbucher +7 more
wiley +1 more source
Abstract Purpose The purpose of the study was to suggest a new method to calculate the intraocular lens (IOL) power in paediatric cataracts targeting emmetropia at the age of 15 years. Methods Data of children younger than 15 years who underwent cataract surgery with IOL implantation between 2005 and 2020 in the ophthalmological department of Marseille
Florence Dupessey +4 more
wiley +1 more source
Trypan blue-assisted posterior capsulorhexis in pediatric cataract surgery [PDF]
Ayman Lotfy,1,2 Ayman Abdelrahman1,2 1Ophthalmology Department, Zagazig University Hospital, 2Alpha Vision Center, Zagazig, Egypt Purpose: To evaluate the safety and efficacy of staining the posterior capsule with trypan blue during capsulorhexis in ...
Abdelrahman A, Lotfy A
core
Different strokes for anterior capsulorhexis in pediatric cataract
Background: A successful outcome in pediatric cataract surgery is determined by an intact, curvilinear anterior capsulotomy which is dependent on the type and density of cataract, the morphology of the anterior capsule, and associated anterior segment ...
Goura Chattannavar +2 more
core +1 more source
Dimension reduction for linear separation with curvilinear distances [PDF]
Any high dimensional data in its original raw form may contain obviously classifiable clusters which are difficult to identify given the high-dimension representation.
Hossain, Alamgir +2 more
core
Capsulorhexis rescue after peripheral radial tear-out: Quick-pull technique
We describe a technique to rescue the continuous curvilinear capsulorhexis (CCC) in cases in which complete radial tears make it impossible to use normal traction forceps. A circumferential path and rapid movement are applied in the plane of the anterior
Paula, Jayter Silva +3 more
core +1 more source
Background!#!In this study, the tear resistance of porcine lens capsules after continuous curvilinear capsulorhexis (CCC) and femtosecond (fs)-laser-assisted capsulotomy for cataract surgery (FLC) with different laser parameters is measured with a custom-
Bartram, Martin +8 more
core +1 more source
Indocyanine Green-assisted Phacoemulsification in Cases of Complicated or Simple Advanced Cataracts
During phacoemulsification for advanced cataracts, particularly when complicated by anterior segment abnormalities, capsulorhexis is very difficult and carries a high risk of complications.
Yi-Sheng Chang +4 more
doaj +1 more source
PURPOSE: To compare the features of capsulotomy obtained during femtosecond laser-assisted cataract surgery with those of continuous curvilinear capsulorhexis (CCC) obtained using a standard manual technique.
MATTEI, PETER ANGELO +7 more
core +1 more source

