Numerical study on aerodynamic noise performances of axial spacing in a contra-rotating axial fan [PDF]
In order to study the effect of axial spacing on behaviors of aerodynamic performance and aerodynamic noises in a contra-rotating fan, the steady/unsteady Reynolds-averaged Navier-Stokes equations are solved by the numerical method in conjunction with a SST turbulence model, and the effects of axial spacing on performance and aerodynamic ...
Hengxuan Luan +4 more
openaire +3 more sources
A fully reversible axial fan with two contra-rotating impellers [PDF]
The objective of this paper is the design, manufacture and test of a fully reversible axial fan. The fundamental layout of the fan chosen consists of two identical contra-rotating impellers without guide vanes, placed in mirror image to each other in a duct-type housing.
Bamberger, Konrad +2 more
openaire +3 more sources
Performance and Flow Conditions of Contra-Rotating Small-Sized Axial Fan
Small-sized axial fans are used as air cooler for electric equipments. But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices. Therefore, higher rotational speed design is conducted although, it causes the deterioration of efficiency and the increase of noise.
Toru Shigemitsu +3 more
openaire +2 more sources
Mechanism of irreversible energy loss in impeller of contra-rotating axial fan
With the urgent need of energy saving and consumption reduction in today's world, the topic of increasing the energy conversion efficiency of ventilation fans has been attracted a lot of attentions, it has become a key issue in the field of ventilation ...
Yongping CHEN +6 more
doaj +2 more sources
Energy transfer process and evolution characteristics in impeller of contra-rotating axial fan
Energy is transferred to the airflow during the rotation of impeller. In engineering, the efficient energy conversion is a key issue. Mastering the energy transfer process in impeller is the premise and basis for realizing efficient energy conversion. In
Yongping CHEN +5 more
doaj +2 more sources
The present paper is an attempt in understanding the stall inception mechanism in a low speed, contra rotating axial flow fan stage, using wavelet transforms.
Tegegn Dejene Toge, A. M. Pradeep
doaj +5 more sources
Numerical investigation of recess casing treatments in axial flow fans [PDF]
T he casing treatment technique for the axial fan has never been more significant since its potential applications were recognized in gas turbines, tunnel ventilation and many other industrial applications where the axial fan would benefit from the ...
Ghila, Abdurazag M.
core +7 more sources
Design and Experimental Validation of a Ducted Counter-rotating Axial-flow Fans System [PDF]
An experimental study on the design of counter-rotating axial-flow fans was carried out. The fans were designed using an inverse method. In particular, the system is designed to have a pure axial discharge flow.
NOURI, Hussain +9 more
core +1 more source
Influence of design parameters on the global performances of low-speed counter-rotating axial-flow fans [PDF]
The present work aims at experimentally investigating the effects of some parameters on the performances of a counter-rotating stage, and on the instationary flow between the rotors.
BAKIR, Farid +5 more
core +1 more source
Numerical analysis of noise characteristics of a contra-rotating axial fan
Numerical analysis of the flow-field in a contra-rotating fan has been performed by using the CFD method. The LES technique is applied to simulate the 3D unsteady whole flow-field of the fan. Several monitoring faces are specified in the flow-field between the two impellers.
F Fang, Q G Chen
openaire +1 more source