Results 91 to 100 of about 331,435 (254)
Coarse‐grained (left) and atomistic (right) models of the shape memory polymer ESTANE ETE 75DT3 are shown schematically. The two representations bridge molecular detail and mesoscopic description. Both models capture shape memory behavior, linking segmental mobility and conformational relaxation of anisotropic chains to macroscopic recovery, and ...
Fathollah Varnik
wiley +1 more source
The Effect of Different Field of View Sizes on Contrast-to-Noise Ratio of Cone-Beam Computed Tomography Units: An In-Vitro Study. [PDF]
Niktash A, Mehralizadeh S, Talaeipour A.
europepmc +1 more source
Low‐voltage FIB‐SEM tomography combined with a image preprocessing pipeline improves phase contrast and enables reliable machine‐learning segmentation of conductive networks in lithium‐ion battery electrodes. Structural descriptors are extracted from segmented images, done semimanually and automated, and compared.
Lisa Beran +6 more
wiley +1 more source
Background/Objectives: Most brain magnetic resonance imaging (MRI) is performed in supine position, although posture may influence cerebrovascular signal characteristics through gravity-related physiological changes.
Chang-Soo Yun +7 more
doaj +1 more source
This study applies machine learning regression to predict chromium layer thickness in decorative trivalent chromium electroplating, using 441 experiments from laboratory‐scale (1L) and pilot‐scale (14L) setups. Tree‐based models, particularly CatBoost, outperformed linear regression by capturing nonlinear parameter interactions (R2$R^2$ up to 0.77 ...
Christoph Baumer +4 more
wiley +1 more source
Assessment of subjective image quality, contrast to noise ratio and modulation transfer function in the middle ear using a novel full body cone beam computed tomography device. [PDF]
Heikkinen AK +5 more
europepmc +1 more source
Grain boundary triple junctions are an essential ingredient of the microstructure of polycrystalline materials. In this study, a triple junction is observed using atomic‐resolution scanning transmission electron microscopy and characterized. Computer simulations reveal that the junction has a dislocation character that is determined by the joining ...
Tobias Brink +4 more
wiley +1 more source
A Practical Noise2Noise Denoising Pipeline for High‐Throughput Raman Spectroscopy
A lightweight and reproducible denoising pipeline for high‐throughput Raman spectroscopy is introduced, based on a 1D convolutional autoencoder trained with a Noise2Noise strategy. Using only repeated short‐exposure acquisitions, the method suppresses stochastic noise without reference spectra, enabling reliable spectral reconstruction while preserving
David Martin‐Calle +5 more
wiley +1 more source
Experiments and thermophysical simulations were conducted to investigate the electron beam powder bed fusion electron beam (PBF‐EB/M) process for the γ′‐strengthened nickel‐based superalloy Inconel 738LC. The results demonstrate the impact of process‐induced microstructural variations on high‐temperature mechanical behavior, providing a basis for ...
Jan Niklas Petenati +11 more
wiley +1 more source
Initial quality performance results using a phantom to simulate chest computed radiography
The aim of this study was to develop a homemade phantom for quantitative quality control in chest computed radiography (CR). The phantom was constructed from copper, aluminium, and polymenthylmethacrylate (PMMA) plates as well as Styrofoam materials ...
Muhogora Wilbroad +2 more
doaj

