Results 131 to 140 of about 2,242,967 (259)

Reconfigurable Logic‐in‐Memory Operations Enabled by Triple‐Gated Feedback Field‐Effect Transistors for Area‐Efficient Computing

open access: yesAdvanced Engineering Materials, EarlyView.
A reconfigurable logic‐in‐memory cell composed of triple‐gated feedback field‐effect transistors implements multiple combinational logic functions within a single configuration. By utilizing program gates as dynamic input terminals, the proposed cell performs full adder, full subtractor, 2‐to‐1 multiplexer, and 4‐to‐2 encoder operations without ...
Minhyeok Seol   +5 more
wiley   +1 more source

Segmentation of low contrast-to-noise ratio images applied to functional imaging using adaptive region growing

open access: yes, 2009
Segmentation in medical imaging plays a critical role easing the delineation of key anatomical functional structures in all the imaging modalities. However, many segmentation approaches are optimized with the assumption of high contrast, and then fail ...
Bailey, A   +4 more
core   +1 more source

Triple Junctions as Dislocation‐Like Defects: The Role of Grain Boundary Crystallography Revealed by Experiment and Atomistic Simulation

open access: yesAdvanced Engineering Materials, EarlyView.
Grain boundary triple junctions are an essential ingredient of the microstructure of polycrystalline materials. In this study, a triple junction is observed using atomic‐resolution scanning transmission electron microscopy and characterized. Computer simulations reveal that the junction has a dislocation character that is determined by the joining ...
Tobias Brink   +4 more
wiley   +1 more source

Initial quality performance results using a phantom to simulate chest computed radiography

open access: yesJournal of Medical Physics, 2011
The aim of this study was to develop a homemade phantom for quantitative quality control in chest computed radiography (CR). The phantom was constructed from copper, aluminium, and polymenthylmethacrylate (PMMA) plates as well as Styrofoam materials ...
Muhogora Wilbroad   +2 more
doaj  

Defect Evolution and Mechanical Performance of Fused Filament Fabrication‐Manufactured 17‐4PH Stainless Steel Revealed by X‐Ray Computed Tomography

open access: yesAdvanced Engineering Materials, EarlyView.
X‐ray computed tomography reveals how process‐induced defects evolve from green to sintered states in Fused Filament Fabrication (FFF)‐manufactured 17‐4PH stainless steel. Internal porosity, weakest cross‐sections, and fracture locations show strong correlation with tensile performance, demonstrating the potential of computed tomography (CT)‐based ...
György Ledniczky   +3 more
wiley   +1 more source

Influence of Scan Strategies in Electron Beam Powder Bed Fusion on Solidification, Microstructure, and High‐Temperature Compressive Properties of γ′‐Strengthened Inconel 738LC

open access: yesAdvanced Engineering Materials, EarlyView.
Experiments and thermophysical simulations were conducted to investigate the electron beam powder bed fusion electron beam (PBF‐EB/M) process for the γ′‐strengthened nickel‐based superalloy Inconel 738LC. The results demonstrate the impact of process‐induced microstructural variations on high‐temperature mechanical behavior, providing a basis for ...
Jan Niklas Petenati   +11 more
wiley   +1 more source

Evaluation of Low Contrast Detectability using Signal-to-noise Ratio in Computed Tomography

open access: yes, 2007
In this paper, we proposed a new quantitative evaluation method of low-contrast detectability for computed tomography(CT)images. It is well known that the contrast-noise-ratio is not enough for CT images to evaluate the low-contrast detectability as ...
大橋, 一也   +10 more
core  

All‐in‐One Analog AI Hardware: On‐Chip Training and Inference with Conductive‐Metal‐Oxide/HfOx ReRAM Devices

open access: yesAdvanced Functional Materials, EarlyView.
An all‐in‐one analog AI accelerator is presented, enabling on‐chip training, weight retention, and long‐term inference acceleration. It leverages a BEOL‐integrated CMO/HfOx ReRAM array with low‐voltage operation (<1.5 V), multi‐bit capability over 32 states, low programming noise (10 nS), and near‐ideal weight transfer.
Donato Francesco Falcone   +11 more
wiley   +1 more source

Liquid Phase Transmission Electron Microscopy: A Window into the Early Stages of Complex Material Formation

open access: yesAdvanced Functional Materials, EarlyView.
Liquid‐phase transmission electron microscopy enables direct observation of nucleation and growth processes in solution. This review is dedicated to the remembrance of Helmut Cölfen and highlights recent studies on complex materials—oxides, biominerals, organic–inorganic crystals—which were central to his research activity. It summarizes key milestones,
Charles Sidhoum   +5 more
wiley   +1 more source

Predicting fan noise propagation in aeroengine bypass ducts

open access: yes, 2009
This thesis explores the prediction of rearwards fan noise propagation within the bypass duct and its radiation into the far feld. Two recently developed models: B-induct and GXMunt, are exploited in application to real engine bypass ducts and their ...
McAleer, Claire Roisin
core  

Home - About - Disclaimer - Privacy