Results 61 to 70 of about 4,692,466 (299)

Electrochemical Behavior of Flame‐Sprayed Sc‐Doped AlCoCrFeMo High‐Entropy Alloy Coatings in 3.5% Sodium Chloride Solution

open access: yesAdvanced Engineering Materials, EarlyView.
Scandium (Sc)‐doped AlCoCrFeMo HEA coatings are fabricated via flame spraying with 0.1, 0.3, and 0.5 wt% Sc additions. Among these, the HEA‐Sc0.3 coating exhibits the highest corrosion resistance, indicated by a more positive corrosion potential and lower current density.
Pankaj Kumar   +7 more
wiley   +1 more source

Entropy‐Driven Design of Low‐Melting‐Point Alloys via Compositionally Complex Strategy

open access: yesAdvanced Engineering Materials, EarlyView.
Conventional low‐melting‐point alloys (LMPAs) are limited by a narrow compositional space and inherent property trade‐offs. This review presents an entropy‐driven design strategy that overcomes these limitations, ushering in a new class of low‐melting‐point compositionally complex alloys (LMCCAs).
Yinghui Shang   +6 more
wiley   +1 more source

Safety Profile of Musculoskeletal Contrast-Enhanced Ultrasound with Sulfur Hexafluoride Contrast Agent

open access: yes, 2020
Christian Fischer,1,* Pierre Kunz,1,* Marten Strauch,1 Marc-André Weber,2 Julian Doll1 1Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Ultrasound Center, HTRG - Heidelberg Trauma Research Group, Heidelberg University Hospital ...
Fischer C   +4 more
core  

3D‐Printed Titanium Gyroid Scaffold Structure Integrated With Tough Hybrid Materials for Cartilage Replacement

open access: yesAdvanced Engineering Materials, EarlyView.
This study proposes a potential device design for joint cartilage replacement. Silica‐polytetrahydrofuran (SiO2‐PolyTHF) hybrids with customizable mechanical properties were developed to mimic the characteristics of a natural meniscus. These were synthesized through a two‐pot sol–gel hybrid process.
Yu‐Chien Lin   +12 more
wiley   +1 more source

Contrast-enhanced ultrasound findings in a case of renal extramedullary hematopoiesis.

open access: yes, 2013
We present the case of an 80-year-old man with two renal solid masses found at sonography, which were imaged by contrast-enhanced ultrasound, CT, and MRI and confirmed histologically. Contrast-enhanced ultrasound findings suggested a benign mass and a CT-
Sabato M   +5 more
core   +1 more source

Anticorrosive Performance of Smart Epoxy Coatings With Poly(urea‐formaldehyde) Microcapsules Filled With 5‐Ethylidene‐2‐norbornene

open access: yesAdvanced Engineering Materials, EarlyView.
PUF/ENB microcapsules were synthesized based on a sequential factorial design and incorporated into an epoxy matrix. Their anticorrosive action, associated with the self‐healing mechanism, demonstrated that the addition of microcapsules to the coating improved anticorrosive performance compared to pure epoxy coatings, particularly when the encapsulate ...
Vandicleya Alves Moreira   +6 more
wiley   +1 more source

Diagnosis and analysis of xanthogranulomatous cholecystitis by ultrasound and contrast-enhanced ultrasound

open access: yes肿瘤影像学, 2018
Objective: To analyze the ultrasonic and contrast-enhanced ultrasonic characteristics of xanthogranulomatous cholecystitis (XGC). Methods: Totally 15 cases of XGC confirmed by surgical pathology in the last 3 years were reviewed and their ultrasonic and ...
JIA Chao   +5 more
doaj  

Gyroid Structured Globugraphite Carbon Foam With Hierarchical and Tailored Pore Size

open access: yesAdvanced Engineering Materials, EarlyView.
Secondary sacrificial templates were designed and printed to create a defined network within a porous carbon. Lattices thermally degrades during the sintering process. Lattices are imprinted into the ceramic template and transferred to the morphology of Globugraphite.
Christiane Roller   +6 more
wiley   +1 more source

Alignment of contrast enhanced medical images [PDF]

open access: yes, 2009
The re-alignment of series of medical images in which there are multiple contrast variations is difficult. The reason for this is that the popularmeasures of image similarity used to drive the alignment procedure do not separate the influence of ...
Melbourne, A.
core  

Dynamic contrast-enhanced ultrasound for quantification of tissue perfusion

open access: yes, 2015
Dynamic contrast-enhanced ultrasound (US) imaging, a technique that uses microbubble contrast agents with diagnostic US, has recently been technically summarized and reviewed by a European Federation of Societies for Ultrasound in Medicine and Biology ...
Schreiber-Dietrich, Dagmar   +4 more
core   +1 more source

Home - About - Disclaimer - Privacy