Results 221 to 230 of about 86,650 (298)

Functional alignment in robotic total knee arthroplasty provides favourable outcomes and minimal early revisions: A systematic review and meta‐analysis

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, EarlyView.
Abstract Purpose Functional alignment (FA) has emerged as a personalised alignment strategy in total knee arthroplasty (TKA), enabled by robotic‐assisted technology. Although early clinical results are encouraging, evidence remains heterogeneous and long‐term safety is uncertain.
Vasileios Giovanoulis   +6 more
wiley   +1 more source

CLASS‐MRI validates patient‐specific ACL footprints across variable fluoroscopic C‐arm positioning: A cadaveric study

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, EarlyView.
Abstract Purpose The aim of this study was (1) to investigate the accuracy of identifying the femoral and tibial anterior cruciate ligament (ACL) footprints (FPs) using the Compressed Lateral and Anteroposterior Anatomical Systematic Sequences (CLASS) method compared to the to the gold standard (anatomical dissection with direct FP marking, referred to
Grégoire Thürig   +6 more
wiley   +1 more source

Superior patient‐reported clinical outcomes after patient‐individual total knee arthroplasty compared with off‐the‐shelf robotic‐assisted total knee arthroplasty in valgus knee phenotypes

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, EarlyView.
Abstract Purpose To compare early patient‐reported clinical outcomes of patient‐individual total knee arthroplasty (TKA) with individualized trochlear design versus robotic‐assisted TKA using off‐the‐shelf implants in patients with valgus knee phenotypes and pronounced femoral valgus (lateral distal femoral angle [LDFA] < 85°) at 3 and 12 months ...
Lars‐Rene Tuecking   +5 more
wiley   +1 more source

Weight‐bearing computed tomography reveals greater anterior tibial translation and femorotibial rotation than magnetic resonance imaging in chronic anterior cruciate ligament deficiency: A prospective observational study

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, EarlyView.
Abstract Purpose To compare anterior tibial translation and femorotibial rotation measurements obtained from conventional supine, non‐weight‐bearing magnetic resonance imaging (MRI) and weight‐bearing computed tomography (WBCT) in patients with chronic anterior cruciate ligament (ACL) tears. Methods WBCT of the knee acquired in full extension and at 30°
Renata Vidal Leão   +8 more
wiley   +1 more source

Improving enteral nutrition in patients requiring neurological intensive care unit care: A retrospective study on a novel bedside nasointestinal tube placement technique

open access: yesNutrition in Clinical Practice, EarlyView.
Abstract Background This study aimed to develop and assess a bedside nasojejunal tube placement technique designed for resource‐limited settings to address the specific challenges of enteral nutrition (EN) delivery in neurocritical care patients, particularly those at high risk of reflux and aspiration. The technique sought to overcome the drawbacks of
Niuchenglin   +5 more
wiley   +1 more source

Kaposiform hemangioendothelioma: Diagnosis and treatment

open access: yesPediatric Investigation, EarlyView.
Vascular endothelial growth factor‐C (VEGF‐C)/vascular endothelial growth factor receptor‐3 (VEGFR‐3) and angiopoietin‐2 (Ang‐2)/tyrosine kinase with immunoglobulin‐like and EGF‐like domain 2 (TIE2) signaling pathways play an important role in lymphangiogenesis.
Yi Tian   +5 more
wiley   +1 more source

Adipose‐derived and bone marrow aspirate concentrate injections for osteoarthritis: A scoping review

open access: yesPM&R, EarlyView.
Abstract Background Osteoarthritis is a leading cause of disability worldwide, and cell‐based treatments including adipose‐derived and bone marrow aspirate have been sought by the lay and medical community as treatment options. Objective To perform a scoping review of published literature on cell‐based injections allowed by the U.S.
Leonardo P. Oliveira   +12 more
wiley   +1 more source

Ultrasound Characterization of Plastic Bonded Explosives With Varied Binder Content and Density

open access: yesPropellants, Explosives, Pyrotechnics, EarlyView.
ABSTRACT Advanced explosive formulations and methods of production require rapid characterization for both processes and materials. Here, we present results for ultrasound characterization of a plastic bonded explosive (PBX) formulation as a function of binder weight percent and pressing density using through‐transmission sound speed measurements.
Jordan S. Lum   +6 more
wiley   +1 more source

Diagnostic performance and reader confidence of MRI-derived CT-like images in patients with femoral head necrosis. [PDF]

open access: yesEur Radiol Exp
Herr FL   +12 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy