Results 61 to 70 of about 5,299 (199)

The MMP‐9/TIMP‐1 Ratio and Concentrations of Osteopontin Are Elevated in Cerebrospinal Fluid of People With Multiple Sclerosis and Decrease After Autologous Hematopoietic Stem Cell Transplantation

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objectives To evaluate the utility of cerebrospinal fluid (CSF) biomarkers—matrix metalloproteinase‐9 (MMP‐9), tissue inhibitor of metalloproteinases‐1 (TIMP‐1), the MMP‐9/TIMP‐1 ratio, and osteopontin (OPN)—as indicators of blood–brain barrier (BBB) integrity and disease activity in people with relapsing–remitting multiple sclerosis (pwMS ...
Ivan Pavlovic   +6 more
wiley   +1 more source

Conversor CA-CC trifásico bidirecional e isolado de único estágio para aplicação em carregadores veiculares multifuncionais

open access: yesEletrônica de Potência
Este artigo apresenta a análise e operação de um conversor CA-CC trifásico, bidirecional e isolado em alta frequência, de único estágio com correção do fator de potência, destinado para aplicação como carregador embarcado de baterias de veículos ...
Rafael Felipe Van Kan   +3 more
doaj   +2 more sources

Inversor Ats

open access: yesEletrônica de Potência, 2011
Neste artigo é apresentada uma nova topologia de inversor baseado na ação de tensão série (ATS) usado para gerar níveis de tensão adicionais. Este inversor será chamado de Inversor ATS. O Inversor ATS apresenta uma série de vantagens sobre os inversores
Euzeli Cipriano dos Santos Júnior
doaj   +1 more source

Dimensionamento de sistemas fotovoltaicos [PDF]

open access: yes, 2009
Monografia de apoio às aulas da disciplina de Projecto Interdisciplinar II do Mestrado Integrado em Engenharia Têxtil.Em termos económicos, o desenvolvimento das nações está intimamente ligado ao consumo e ao preço da energia.
Carneiro, Joaquim A. O.
core  

In‐Depth Profiling Highlights the Effect of Efgartigimod on Peripheral Innate and Adaptive Immune Cells in Myasthenia Gravis

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background Myasthenia gravis (MG) is an autoimmune disorder characterized by antibody‐mediated complement activation. Efgartigimod, a neonatal Fc receptor (FcRn) antagonist, is approved for treating generalized MG (gMG). However, its modulatory effects on upstream innate and adaptive immune cells remain largely unexplored.
Lei Jin   +11 more
wiley   +1 more source

Uma fonte chaveada de fator de potência na forma de fonte simétrica.

open access: yesRevista Tecnologia, 2009
Este trabalho propõe a concepção de uma fonte chaveada com correção de fator de potência, obtida através de uma integração de soluções, ou seja, a associação de um conversor ca/cc e dois conversores cc/cc.
Fernando Lessa Tofoli   +1 more
doaj  

Meningovascular Inflammation in Cerebral Amyloid Angiopathy‐Related Cortical Superficial Siderosis

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT The role of inflammation in cortical superficial siderosis (cSS), a marker of cerebral amyloid angiopathy (CAA) linked to high hemorrhage risk, is unclear. We examined 15 patients with cSS using 3 T post‐contrast vessel wall MRI (VWI) and CSF analysis.
Philipp Arndt   +8 more
wiley   +1 more source

The temporal trends and short‐ and long‐term mortality of people with acute myocardial infarction and rheumatoid arthritis: a nationwide cohort study

open access: yesArthritis Care &Research, Accepted Article.
Aims We investigated whether a diagnosis of rheumatoid arthritis (RA) affects the quality of inpatient acute myocardial infarction (AMI) care and long‐term mortality post‐AMI. Methods We analysed data from 784,091 adults, 6,047 with a diagnosis of RA, from England and Wales hospitalised with AMI between 2005 and 2019 from the MINAP registry, linked ...
Megan Butler   +8 more
wiley   +1 more source

Cálculo de Esforço nos Semicondutores do Inversor Fonte Z

open access: yesEletrônica de Potência, 2016
Este trabalho apresenta o cálculo dos esforços de corrente nos semicondutores do inversor fonte Z trifásico operando com a modulação Boost Simples. O inversor fonte Z possui uma malha de impedância conhecida como malha Z, que possibilita realizar as ...
Vitor T. Odaguiri   +2 more
doaj   +1 more source

Diseño e implementación de un control difuso para una estación didáctica de temperatura [PDF]

open access: yes, 2014
En los últimos años el modelado de sistemas de control no lineales ha requerido de soluciones muy complejas y muy rápidas en su respuesta; el control difuso basado en reglas y también orientado al mejoramiento de las características del control “clásico”
Guzmán Jaramillo, Jorge Hernán   +1 more
core  

Home - About - Disclaimer - Privacy