Results 141 to 150 of about 280,908 (290)
A Case Study on the Impact of Solar Reflectance Attenuation and Roof Cleaning on a Cool Roof Return on Investment [PDF]
: Research has shown roofing systems with high solar reflectance and thermal emissivity lead to less heat absorption, a consequential reduction in cooling load demand, and a resultant reduction on energy expenditure.
core
ABSTRACT Sustainable Building Designs and Practices (SBDPs) are increasingly important for reducing environmental impacts, conserving resources, and improving occupant well‐being. This study examines New Zealand building professionals' perceptions of the integration and performance of energy efficiency (EE), water efficiency (WE), and Indoor ...
Tharaya Poorisat +3 more
wiley +1 more source
Solar Roof Cooling by Evaporation
Evaporation is nature's way of cooling. By spraying a light film of water in the form of a mist for thirty seconds, then turning the sprays off for five minutes while evaporation takes place, the roof temperature can be reduced from 1650o to 880o.
Patterson, G. V.
core
ABSTRACT The adoption of solar photovoltaic systems (SPVS) in passive houses (PHs) is shaped by technical, economic and policy‐related factors. Yet, the interactions among these factors have not been quantitatively modelled in the New Zealand context.
Franklin Chukwuebuka Nkado +3 more
wiley +1 more source
Paint baking of resistance spot welded joints of 2.0 GPa warm‐stamped medium‐Mn steel activates low‐temperature tempering, forming fine cementite in the fusion zone and enhancing toughness. Crack propagation resistance increases, shifting the failure mode from partial interfacial to complete pullout, with peak load and energy absorption rising ...
Sunusi Marwana Manladan +8 more
wiley +1 more source
The high‐strain‐rate behavior of resistance spot‐welded DP800–DP1000 joints is investigated. Results show that microstructural gradients across BM–HAZ–FZ govern hardness, strain rate sensitivity, and failure modes. While strength increases with strain rate, energy absorption is controlled by ductility, with DP800–DP800 joints showing superior ...
Pankaj Shrivastava, Velaphi Msomi
wiley +1 more source
Il panorama climatico italiano, caratterizzato da elevati livelli di irraggiamento solare, rende necessaria un’attenta valutazione delle prestazioni energetiche degli edifici nello scenario estivo.
BELPOLITI, Vittorino
core
Molten aluminum–water explosion triggered by leakage remains the core unresolved safety hazard hindering safe production in aluminum direct chill casting. This review summarizes its explosion mechanism, key influencing factors, prevention technologies, existing gaps, and prospects of intelligent multi‐technology integrated explosion‐proof systems ...
Min Wang +5 more
wiley +1 more source
Concrete in architecture: Redefining form, space, function, and insights from bibliometric analysis
Abstract Concrete has become a cornerstone in architectural and engineering innovation, as it seamlessly integrates structural performance with artistic expression. Its evolution from ancient opus caementicium to contemporary ultra‐high‐performance concrete illustrates its adaptability to the change in technological, environmental, and design paradigms.
Mouhcine Benaicha +2 more
wiley +1 more source
Abstract Ground granulated blast‐furnace slag (GGBS) is a widely used clinker substitute in concrete, recognized for its potential to significantly reduce environmental impacts. However, its application in prestressed concrete remains limited in several countries, mainly due to concerns regarding early‐age mechanical performance and long‐term ...
D. Rolando Baldiviezo +6 more
wiley +1 more source

