Results 251 to 260 of about 2,728,523 (290)
Some of the next articles are maybe not open access.

A Method for Sectioning Saturated Soil Cores

Soil Science Society of America Journal, 1976
Abstract A simple system for sectioning water‐saturated cores without prior freezing is described. The method described can be used for studying the distribution and movement of ions in soil or sediment cores prepared in the laboratory or obtained in undisturbed form from the field.
K. R. Reddy, W. H. Patrick
openaire   +1 more source

Dynamic core length in saturated core fault current limiters

Superconductor Science and Technology, 2013
A saturated core fault current limiter (SCFCL) is a non-linear core-reactor where the core is saturated by an external superconducting DC bias source to achieve a low core permeability at nominal AC currents. Fault current levels in the AC coils de-saturate the core and transform it to a higher permeability state, hence limiting the fault current.
Y Nikulshin   +3 more
openaire   +1 more source

A Technique for Detecting Incomplete Saturation of Cores

Journal of Petroleum Technology, 1978
Cores and core plugs are cleaned, dried, and saturated with brine or oil as part of many measuring procedures. The validity of the measurements depends directly on saturation being complete without any trace of residual gas in the core. Errors introduced by residual gas vary from about a square-root dependence for formation factor, through a linear ...
openaire   +1 more source

PWM inverter controlled by a small saturable core

IEEE Transactions on Magnetics, 1987
A sinusoidal PWM inverter with MOSFETs controlled by an extremely small magnetic core is presented, which is simple and of high efficiency under high frequency switching. The circuit is based on the principle of the transistor core multivibrator. However the saturable core is used for PWM in the gate drive circuit.
K. Harada, H. Sakamoto
openaire   +1 more source

Core Saturation Blocking Oscillator Control

Review of Scientific Instruments, 1959
The parameters that control a blocking oscillator's pulse shape are reviewed. Limitations in previous techniques of pulse duration control are described. It is shown that the pulse duration may be determined either by tube (or transistor) saturation or by saturation of the transformer core material.
openaire   +1 more source

Electromagnetic design of saturated iron core SFCL

2011 International Conference on Applied Superconductivity and Electromagnetic Devices, 2011
The most attractive advantage of a saturated iron core SFCLs (SIC-SFCL) is that its impedance can change from very low in normal power transmission to very high for fault current limiting. This characteristic is achieved by varying the electromagnetic states in the main body of the device, including the iron cores, the ac working coils, and the dc bias
Jing Yin Zhang   +4 more
openaire   +1 more source

Screening for HVDC system core saturation instability

IEEE Transactions on Power Delivery, 2000
Core saturation instability is a condition resulting from excess low-order harmonic AC/DC system interactions, amplified by increasing transformer flux offset which, in turn, is driven by the interaction between the harmonics and the converter. A small signal analysis method has been successfully applied to efficiently screen a variety of conditions ...
T. Hasegawa   +7 more
openaire   +1 more source

Current sensors with a small saturable core and MOSFETs

IEEE Transactions on Magnetics, 1988
Simple, noncontact-type current sensors for detecting instantaneous value of the current are reported. The sensor are especially suitable for DC-to-DC converters and uninterruptible power supplies. The circuits are based on the principle of the transistor-core multivibrator, in which MOSFETs are used for switching.
K. Harada, H. Sakamoto
openaire   +1 more source

Saturated-core resonant fault current limiter

2015 Clemson University Power Systems Conference (PSC), 2015
In this paper, a new design of a series-type resonant fault current limiter (ReFCL), based on saturation effects, called a saturated-core ReFCL is presented. The saturable core used in the ReFCL plays two key roles, detector and limiter. The proposed ReFCL could be considered as a serious competitor of superconducting FCLs (SFCLs).
Morteza Rezaee   +2 more
openaire   +1 more source

Effect of Pressure Reduction upon Core Saturation

Transactions of the AIME, 1939
Any information that will increase the accuracy of our knowledge of theconditions prevailing in petroleum reservoirs should be of direct value in thedetermination of the proper operating technique as well as in the estimation ofreserves and of ultimate production.
H.G. Botset, M. Muskat
openaire   +1 more source

Home - About - Disclaimer - Privacy