Results 11 to 20 of about 159,105 (150)
Comparison of corneal flap thickness using a FS200 femtosecond laser and a moria SBK microkeratome [PDF]
AIM: To evaluate differences in flap thickness resulting from use of an Alcon Wavelight FS200 femtosecond laser and a MORIA SBK microkeratome when making a 110-μm-thick corneal flap and to identify the potential factors that affect corneal flap thickness.
Jing Zhang +4 more
doaj +3 more sources
Unexpectedly high corneal flap thickness and ectasia after mechanical LASIK
LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative ...
José Belucio Neto +3 more
doaj +2 more sources
Biomechanical corneal changes induced by different flap thickness created by femtosecond laser [PDF]
OBJECTIVE: To evaluate the impact of the creation of corneal flaps at different thicknesses on the biomechanical properties of swine corneas. METHOD: Twelve swine eyes were obtained to form two groups: 100 μm flap thickness and 300 μm flap ...
Fabricio W. Medeiros +3 more
doaj +2 more sources
Iyad A Goussous,1 Mohamed-Sameh El-Agha,1 Ahmed Awadein,1 Mohamed H Hosny,1 Alaa A Ghaith,2 Ahmed L Khattab2 1Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, 2Faculty of Medicine, Alexandria University, Alexandria, Egypt ...
Goussous IA +5 more
doaj +1 more source
Yunus Karabela,1 Orkun Muftuoglu,2 Faruk Kaya1 1Department of Ophthalmology, Medipol University, 2Department of Ophthalmology, Vehbi Koç Vakfi Amerikan Hospital, Istanbul, Turkey Purpose: This study aimed to evaluate the accuracy and consistency
Karabela Y, Muftuoglu O, Kaya F
doaj +1 more source
Effects of Aberrant Pax6 Gene Dosage on Mouse Corneal Pathophysiology and Corneal Epithelial Homeostasis [PDF]
Background: Altered dosage of the transcription factor PAX6 causes multiple human eye pathophysiologies. PAX6(+/-) heterozygotes suffer from aniridia and aniridia-related keratopathy (ARK), a corneal deterioration that probably involves a limbal ...
Fullwood, Nigel J. +34 more
core +5 more sources
Aerodynamic and performance characteristics of a passive leading edge Kruger flap at low Reynolds numbers [PDF]
An experimental and numerical study was performed on a Clark Y aerofoil with a 10% chord leading edge Kruger flap to examine its aerodynamic performance at Reynolds numbers of 0.6 × 106, 1 × 106, and 1.6 × 106, to help to identify the forces and ...
Garry, Kevin P. +2 more
core +7 more sources
Kinematic Simulation and Structure Analysis of a Morphing Flap [PDF]
This thesis presents a study on the design and analysis of a morphing flap structure integrated with actuation mechanism for potential application to large aircraft.
Guo, Shixian
core +7 more sources
Effects of the LASIK flap thickness on corneal biomechanical behavior: a finite element analysis
Background It is well known that the biomechanical properties change after LASIK refractive surgery. One reason is the impact of flap creation on the residual stroma. The results have revealed that the change is closely related with the flap thickness in
Lihua Fang +5 more
doaj +1 more source
Purpose: To study whether a customized elliptical flap configuration offers any visual, refractive, or biomechanical advantage over the “conventional” circular flaps in patients undergoing myopic laser in situ keratomileusis (LASIK).
Amit Gupta +5 more
doaj +1 more source

