Results 11 to 20 of about 159,105 (150)

Comparison of corneal flap thickness using a FS200 femtosecond laser and a moria SBK microkeratome [PDF]

open access: yesInternational Journal of Ophthalmology, 2014
AIM: To evaluate differences in flap thickness resulting from use of an Alcon Wavelight FS200 femtosecond laser and a MORIA SBK microkeratome when making a 110-μm-thick corneal flap and to identify the potential factors that affect corneal flap thickness.
Jing Zhang   +4 more
doaj   +3 more sources

Unexpectedly high corneal flap thickness and ectasia after mechanical LASIK

open access: yesRevista Brasileira de Oftalmologia, 2023
LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative ...
José Belucio Neto   +3 more
doaj   +2 more sources

Biomechanical corneal changes induced by different flap thickness created by femtosecond laser [PDF]

open access: yesClinics, 2011
OBJECTIVE: To evaluate the impact of the creation of corneal flaps at different thicknesses on the biomechanical properties of swine corneas. METHOD: Twelve swine eyes were obtained to form two groups: 100 μm flap thickness and 300 μm flap ...
Fabricio W. Medeiros   +3 more
doaj   +2 more sources

The effect of flap thickness on corneal biomechanics after myopic laser in situ keratomileusis using the M-2 microkeratome

open access: yesClinical Ophthalmology, 2017
Iyad A Goussous,1 Mohamed-Sameh El-Agha,1 Ahmed Awadein,1 Mohamed H Hosny,1 Alaa A Ghaith,2 Ahmed L Khattab2 1Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, 2Faculty of Medicine, Alexandria University, Alexandria, Egypt ...
Goussous IA   +5 more
doaj   +1 more source

Corneal flap thickness with the Moria M2 single-use head 90 microkeratome in 72 consecutive LASIK procedures

open access: yesClinical Ophthalmology, 2017
Yunus Karabela,1 Orkun Muftuoglu,2 Faruk Kaya1 1Department of Ophthalmology, Medipol University, 2Department of Ophthalmology, Vehbi Koç Vakfi Amerikan Hospital, Istanbul, Turkey Purpose: This study aimed to evaluate the accuracy and consistency
Karabela Y, Muftuoglu O, Kaya F
doaj   +1 more source

Effects of Aberrant Pax6 Gene Dosage on Mouse Corneal Pathophysiology and Corneal Epithelial Homeostasis [PDF]

open access: yes, 2011
Background: Altered dosage of the transcription factor PAX6 causes multiple human eye pathophysiologies. PAX6(+/-) heterozygotes suffer from aniridia and aniridia-related keratopathy (ARK), a corneal deterioration that probably involves a limbal ...
Fullwood, Nigel J.   +34 more
core   +5 more sources

Aerodynamic and performance characteristics of a passive leading edge Kruger flap at low Reynolds numbers [PDF]

open access: yes, 2012
An experimental and numerical study was performed on a Clark Y aerofoil with a 10% chord leading edge Kruger flap to examine its aerodynamic performance at Reynolds numbers of 0.6 × 106, 1 × 106, and 1.6 × 106, to help to identify the forces and ...
Garry, Kevin P.   +2 more
core   +7 more sources

Kinematic Simulation and Structure Analysis of a Morphing Flap [PDF]

open access: yes, 2013
This thesis presents a study on the design and analysis of a morphing flap structure integrated with actuation mechanism for potential application to large aircraft.
Guo, Shixian
core   +7 more sources

Effects of the LASIK flap thickness on corneal biomechanical behavior: a finite element analysis

open access: yesBMC Ophthalmology, 2020
Background It is well known that the biomechanical properties change after LASIK refractive surgery. One reason is the impact of flap creation on the residual stroma. The results have revealed that the change is closely related with the flap thickness in
Lihua Fang   +5 more
doaj   +1 more source

Elliptical versus circular flap configuration in myopic eyes undergoing femtosecond laser in situ keratomileusis surgery: A contralateral eye study

open access: yesIndian Journal of Ophthalmology, 2021
Purpose: To study whether a customized elliptical flap configuration offers any visual, refractive, or biomechanical advantage over the “conventional” circular flaps in patients undergoing myopic laser in situ keratomileusis (LASIK).
Amit Gupta   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy