Evaluation of the system accuracy of frameless stereotactic radiosurgery using a combination of cone beam CT, six degrees of freedom couch, and surface image‐guided systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate the accuracy of the frameless linear accelerator‐based stereotactic radiosurgery (FSRS) system incorporating cone‐beam CT (CBCT), six degrees of freedom (6‐DoF) couch, room laser, and surface image‐guided (SG) systems.
Hao‐Wen Cheng   +4 more
wiley   +1 more source

Correction to: An automated group‑housed oral fentanyl self‑administration method in mice. [PDF]

open access: yesPsychopharmacology (Berl)
Peretz-Rivlin N   +6 more
europepmc   +1 more source

Comprehensive clinical evaluation of novel 4DCT‐based lung function imaging methods

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Methods have been developed that apply image processing to 4DCTs to generate 4DCT‐ventilation/perfusion lung imaging. Traditional methods for 4DCT‐ventilation rely on Hounsfield‐Unit (HU) density‐change methods and suffer from poor numerical robustness while not providing 4DCT‐perfusion data.
Ehsan Golkar   +6 more
wiley   +1 more source

Correction to: Feasibility of PET‑enabled dual‑energy CT imaging: First physical phantom and initial patient study results. [PDF]

open access: yesEur J Nucl Med Mol Imaging
Zhu Y   +11 more
europepmc   +1 more source

Open‐source deep‐learning models for segmentation of normal structures for prostatic and gynecological high‐dose‐rate brachytherapy: Comparison of architectures

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The use of deep learning‐based auto‐contouring algorithms in various treatment planning services is increasingly common. There is a notable deficit of commercially or publicly available models trained on large or diverse datasets containing high‐dose‐rate (HDR) brachytherapy treatment scans, leading to poor performance on images ...
Andrew J. Krupien   +8 more
wiley   +1 more source

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

Novel CT radiomics models for the postoperative prediction of early recurrence of resectable pancreatic adenocarcinoma: A single‐center retrospective study in China

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To assess the predictive capability of CT radiomics features for early recurrence (ER) of pancreatic ductal adenocarcinoma (PDAC). Methods Postoperative PDAC patients were retrospectively selected, all of whom had undergone preoperative CT imaging and surgery. Both patients with resectable or borderline‐resectable pancreatic cancer met
Xinze Du   +7 more
wiley   +1 more source