Results 211 to 220 of about 3,175,656 (384)

Improving dose delivery in non‐coplanar cranial SRS: Stereoscopic x‐ray‐guided mitigation of table walkout errors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Purpose Linear accelerator (LINAC)‐based single‐isocenter multi‐target (SIMT) treatment has streamlined the cranial stereotactic radiosurgery (SRS) workflow. Though efficient, SIMT delivery adds additional challenges that should be considered, including increased sensitivity to rotational errors for off‐isocenter targets.
Yohan A. Walter   +4 more
wiley   +1 more source

Machine stability and dosimetry for ultra‐high dose rate FLASH radiotherapy human clinical protocol

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The FLASH effect, induced by ultra‐high dose rate (UHDR) irradiations, offers the potential to spare normal tissue while effectively treating tumors. It is important to achieve precise and accurate dose delivery and to establish reliable detector systems, particularly for clinical trials needed to help the clinical transfer of FLASH‐
Patrik Gonçalves Jorge   +9 more
wiley   +1 more source

Creep Characterization of Inconel 718 Lattice Metamaterials Manufactured by Laser Powder Bed Fusion

open access: yesAdvanced Engineering Materials, EarlyView., 2023
Herein, the creep characteristics of additively manufactured Inconel 718 metamaterials are investigated. The creep behavior of metamaterials and the effects of microstructural defects are assessed, and the microstructure defects are accurately captured using Kachanov's creep damage model.
Akash Singh Bhuwal   +5 more
wiley   +1 more source

Accounting for TLD response to CBCT protocols in external beam radiotherapy dose monitoring

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose LiF thermoluminescent dosimeters (TLDs) are commonly used in radiation therapy to verify the delivered dose. Examples include dose verification for complicated treatment setups or cardiovascular implantable electronic devices (CIEDs). TLDs may be present for both the pre‐treatment imaging kilovoltage (kV) beam and the megavoltage (MV ...
Andrew J. White   +5 more
wiley   +1 more source

Correction of generic name [PDF]

open access: green, 1913
C. Forster-Cooper
openalex   +1 more source

An investigation into the feasibility and efficacy of stereotactic radiosurgery for 1–3 cm single brain lesions on the ring‐mounted Halcyon LINAC

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose An evaluation of the accuracy, safety, and efficiency of the Halcyon ring delivery system (RDS) for stereotactic radiosurgery (SRS) treatment to relatively small (1–3 cm) brain lesions. Methods After completing the extensive in‐house quality assurance checks including Winston–Lutz test and independent dose verification via MD Anderson ...
Kate Hazelwood   +5 more
wiley   +1 more source

Corrigendum: A Quantitative Assessment of Factors Affecting the Technological Development and Adoption of Companion Diagnostics

open access: yesFrontiers in Genetics, 2016
Dee eLuo   +13 more
doaj   +1 more source