Geometric and dosimetric evaluation of a commercial AI auto‐contouring tool on multiple anatomical sites in CT scans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan   +6 more
wiley   +1 more source

Position‐dependent offset corrections for ring applicator reconstruction in cervical cancer brachytherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Due to the tight curvature in their design, ring applicators are usually associated with large positioning errors. The standard practice to correct for these deviations based on global offsets may not be sufficient to comply with the recommended tolerance.
Leon G. Aldrovandi   +3 more
wiley   +1 more source

Professionalism skills education in medical physics residency: Current state and perceived importance

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The purpose of this study was to collect data on current practices for teaching and assessing professionalism in CAMPEP‐accredited residency programs. Methods A survey of 21 questions was sent to 160 program directors (PDs) of CAMPEP‐accredited residency programs.
Anna Rodrigues   +5 more
wiley   +1 more source

Parathyroid Crisis and Thromboembolism: Association or Coincidence? [PDF]

open access: yesAACE Clin Case Rep
Zavgorodneva Z   +3 more
europepmc   +1 more source

Using deep learning generated CBCT contours for online dose assessment of prostate SABR treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Prostate Stereotactic Ablative Body Radiotherapy (SABR) is an ultra‐hypofractionated treatment where small setup errors can lead to higher doses to organs at risk (OARs). Although bowel and bladder preparation protocols reduce inter‐fraction variability, inconsistent patient adherence still results in OAR variability.
Conor Sinclair Smith   +8 more
wiley   +1 more source

Evaluating feature extraction reproducibility across image biomarker standardization initiative‐compliant radiomics platforms using a digital phantom

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin   +5 more
wiley   +1 more source