Results 281 to 290 of about 4,508,086 (298)
Some of the next articles are maybe not open access.

Instrument performance and cross calibration of FY-3C MWRI

2016 IEEE International Geoscience and Remote Sensing Symposium (IGARSS), 2016
The MicroWave Radiation Imager (MWRI) onboard FengYun-3C (FY-3C) Satellite is a total-power radiometer observing earth surface and atmosphere at 10.65, 18.7, 23.8, 36.5 and 89 GHz with dual polarization. The on-orbit test of FY-3C MWRI was performed shortly after the launch of platform. Sensor performance factors include receiver sensitivity black body
Shengli Wu 0002, Jie Chen
openaire   +2 more sources

ScaRaB: first results of absolute and cross calibration

SPIE Proceedings, 2015
ScaRaB (SCAnner for RAdiation Budget) is the name of three radiometers whose two first flight models have been launched in 1994 and 1997. The instruments were mounted on-board Russian satellites, METEOR and RESURS. On October 12th 2011, a last model has been launched from the Indian site of Sriharikota. ScaRaB is a passenger of MEGHA-TROPIQUES, an Indo-
Thierry L. Trémas   +2 more
openaire   +1 more source

Cross-calibration of interferometric SAR data

IEE Proceedings - Radar, Sonar and Navigation, 2003
Generation of digital elevation models from interferometric synthetic aperture radar (SAR) data is a well established technique. Achieving a high geometric fidelity calls for a calibration accounting for inaccurate navigation data and system parameters as well as system imperfections.
openaire   +1 more source

Cross-calibration of axial DEXA systems

Radiography, 2001
With X-ray equipment, it may not be generally appreciated that no two X-ray tubes are exactly the same. When tubes of the same type and specification are used they never give exactly the same radiation output even when powered identically. This is because even with the latest manufacturing techniques, slight variations do occur, even in the same ...
openaire   +1 more source

Synthetic Aperture Radar Radiometric Cross Calibration Based on Distributed Targets

IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing, 2022
Yongsheng Zhou, Fan Zhang, Wen Hong
exaly  

Scatterometer Cross-Calibration Using Antarctica as a Calibration Target

IGARSS 2023 - 2023 IEEE International Geoscience and Remote Sensing Symposium, 2023
Nathan Porter, David G. Long
openaire   +1 more source

Uncertainty analysis of cross-calibration for HJ-1 CCD camera

Science China Technological Sciences, 2013
Zuo Wang   +2 more
exaly  

Report on the cross-calibration of SIMS-instruments

Vacuum, 1990
FD Rüdenauer   +20 more
openaire   +1 more source

Home - About - Disclaimer - Privacy