Effect ofOpening SizeonWind-Driven Cross Ventilation
The opening size is important to the ventilation of building because various opening sizes affects the ventilation performance for building. Therefore, the objective of this study is to investigate the effect of opening size on indoor airflow characteristics of naturally ventilated building model.
Lip Kean Moey +4 more
openaire +3 more sources
Prediction of flow and dispersion in cross–ventilated buildings [PDF]
The present paper presents a detailed computational analysis of flow and dispersion in a generic isolated single–zone buildings. First, a grid generation strategy is discussed, that is inspired by a previous computational analysis and a grid independence study.
Benim, Ali Cemal +2 more
openaire +3 more sources
Smoke movement and control in longitudinal ventilated tunnel fires with cross-passages
This paper studies the characteristics of smoke movement and control in longitudinal ventilated tunnel fires with cross-passages through numerical modeling.
Yongzheng Yao +4 more
doaj +1 more source
Computational fluid dynamics simulations with a Reynolds-averaged Navier-Stokes model were performed for flow fields over a building array and inside a building in the array with different building opening positions. Ten combinations of opening locations
Yuki Murakami +3 more
doaj +1 more source
Natural Cross-ventilation of Buildings, An Experimental Study
AbstractNatural cross ventilation can be a promising passive solution for summer thermal comfort in buildings. It takes advantage of the night temperature of the air to cool the walls of the building. Although this technique is well-known in hot climate, its use in new buildings requires being able to predict the quantity of heat that can be dissipated.
Pabiou, Hervé +3 more
openaire +2 more sources
A two-zone model for natural cross-ventilation [PDF]
Cross-ventilation flows (CV) are characterized by significant inflow momentum conservation as fluid flows across an enclosed rectangular volume as a confined jet. When the inflow area is smaller than the volume cross-sectional area the CV flow has distinct jet and recirculation flow regions.
Carrilho da Graça, G +2 more
openaire +1 more source
Fudo: An East Asian Notion of Climate and Sustainability
My paper discusses an East Asian notion of climate and its significance for sustainability. A particular reference is the environmental philosophy of Tetsuro Watsuji (1889–1960), a Japanese philosopher who reflected upon the meaning of climate, or “fudo”
Jin Baek
doaj +1 more source
Public toilets with insufficient ventilation present high cross infection risk
Due to insufficient ventilation, public toilets present high risks for cross-infection. The study investigated 61 public toilets to identify the causes and locations of biological contaminated sources. Airborne and surface bacterial contamination, carbon
M. C. Jeffrey Lee, K. W. Tham
doaj +1 more source
Recently, people around the world have actively made efforts to conserve energy in residential homes as a countermeasure against global warming. The awareness of the importance of energy saving has continued to grow in Japan since the Great East Japan ...
Tomoyuki Endo +3 more
doaj +1 more source
Study on acquired infection of patients in waiting space of fever clinic [PDF]
Since the COVID-19 outbreak, high numbers of patients with respiratory symptoms flock to fever clinic, cause overcrowding. Due to relatively densely populated space and the existing ventilation strategy, lead to space environment bearing capacity lose ...
Liu Shuo +5 more