Results 11 to 20 of about 4,370,137 (193)
Evaluation of Discharge Coefficients for Window Openings in Wind Driven Natural Ventilation
This paper describes the classical approach for calculation of wind driven airflow through large openings in buildings and discusses the fulfilment of the limiting assumptions.
Heiselberg, P.,, Sandberg, Mats,
core +5 more sources
Impact of eave and roof pitch on cross ventilation for an isolated building with sawtooth roof
An eave refers to an extension attached to the building roof to protect the interior space from direct solar radiation and improve the performance on cross ventilation.
Lip Kean Moey +5 more
doaj +1 more source
Mechanical ventilation consumes a huge amount of global energy. Natural ventilation is a crucial solution for reducing energy consumption and enhancing the capacity of atmospheric self-purification.
Yun Hu +7 more
doaj +1 more source
Wind pressure coefficient distribution of detached houses in a dense residential block
In a dense residential block, external airflow patterns around a site should be analyzed initially in the design stage to improve cross ventilation, thereby improving the comfort of an occupant and saving energy.
Keiichiro Taniguchi, Yoshihiko Akamine
doaj +1 more source
Guidelines on setting the target minute ventilation in Adaptive Support Ventilation
Adaptive Support Ventilation (ASV) is a fully closed loop ventilation where the operator input the desired PEEP, FiO2 and the target minute ventilation (MV) expressed as a percentage according to ideal body weight.
Ehab G. Daoud +4 more
core +1 more source
Feasibility Analysis of Cross Passage Ventilation and Smoke Control in Extra-Long Submarine Tunnel
Longitudinal ventilation fans in extra-long submarine tunnels are usually arranged at both ends of the tunnel limited by the tunnel cross section, which is usually hindered by insufficient power caused by extra-long ventilation distances.
Wenjiao You, Jie Kong
doaj +1 more source
From state-of-the-art ventilation to closed loop ventilation
Recent emphasis on energy load delivered during each ventilatory breath has opened a new insight to reduce harmful ventilatory induced lung injury, but no robust clinical evidence of patient benefit produced yet. Closed loop ventilation is a strategy to
Andreas Schibler +5 more
core +1 more source
Numerical investigation of inlet opening size on wind-driven cross ventilation
The purpose of this study is to investigate the effect of opening size on indoor airflow characteristics of a naturally ventilated building model. The numerical simulation based on 3D-steady RANS equation was performed in this study.
Lip Kean Moey +4 more
doaj +1 more source
As most existing office buildings in China lack fresh air systems for ventilation, natural ventilation with windows remains the main means of improving indoor air quality and adjusting indoor thermal comfort.
Yuanyuan Wang +3 more
doaj +1 more source
Pioneers in Mechanical Ventilation: Björn Jonson
In this article, we highlight one of the pioneers of mechanical ventilation. Dr Björn Jonson is a physiologist, physician and currently a Professor Emeritus at Lund University in Sweden. He has spent the last sixty years of his life dedicated to research
Daoud, Ehab +3 more
core +1 more source