Results 51 to 60 of about 613 (136)
This study developed a novel three‐dimensional (3D)‐printed strut‐type prosthesis for reconstruction of bone defects following hemicortical resection of distal femoral parosteal osteosarcoma. The mid‐term follow‐up results demonstrated that this prosthesis effectively restored limb function and exhibited favorable bone ingrowth and osseointegration ...
Jianhua Mu +10 more
wiley +1 more source
Abstract Objective To describe a repeated‐measures model permitting evaluation of up to four implants intended for maxillofacial applications in sheep. Animals Two‐year‐old Merino wethers (n = 5). Methods A retromandibular subparotid approach was developed through anatomical study of atlases, predissected models and cadaveric experiments.
Reza Sanaei +7 more
wiley +1 more source
The Design of Cruciform Test Specimens for Planar Biaxial Testing of Fabrics for Inflatable Aerodynamic Decelerators [PDF]
A preliminary analytical study was conducted to investigate the effects of cruciform test specimen geometries on strain distribution uniformity in the central gage section under biaxial loads. Three distinct specimen geometries were considered while varying the applied displacements in the two orthogonal directions.
openaire +1 more source
Abstract Objective To investigate the effects of muscle activation on internal tibial rotation and cranio‐caudal translation (CCT) in intact and cranial cruciate ligament (CCL) deficient stifles. Study design Ex vivo biomechanical study. Animals Eight cadaveric, nonpaired canine stifles.
Pavlos Natsios +3 more
wiley +1 more source
Design of Cruciform Test Specimens with different Biaxiality ratios for VHCF Fatigue [PDF]
The necessity to increase performances in terms of lifetime and security in mechanical components or structures is the motivation for intense research in fatigue. Applications range from aeronautic to medical devices. With the development of new materials, there is no longer a fatigue limit in the classical sense, where it was accepted that the fatigue
Montalvão, Diogo +3 more
openaire
Optimum design of cruciform specimen was performed for biaxial loading-fatigue test on the basis of the calculations through elastic finite element method. The stress must be greater in its central thickness-reduced region than in any other regions including four corners in the specimen, since fatigue crack should originate at this site.
HATANAKA, Kenji +4 more
openaire +2 more sources
Biaxial tensile behavior of stainless steel 316L manufactured by selective laser melting. [PDF]
Wang H, Shu X, Zhao J, Alexandrov IV.
europepmc +1 more source
Abstract Background Main desired features of biaxial tests are: uniformity of stresses and strains; high strain levels in gauge areas; reliable constitutive parameters identification. Despite cruciform specimen suitability to modern tensile devices, standard testing techniques are still debated because of difficulties in
openaire +1 more source
Quantifying Alignment Deviations for the In-Plane Biaxial Test System via a Shape-Optimised Cruciform Specimen. [PDF]
Chen J, Zhang J, Zhao H.
europepmc +1 more source
A custom-built planar biaxial system for soft tissue material testing. [PDF]
Pasta S +3 more
europepmc +1 more source

