Results 1 to 10 of about 2,102 (180)
Successful Mediastinal Cryobiopsy Using the Slim UCP190F EBUS Bronchoscope and a 25G Needle: Demonstrating the Efficacy of the Ariza‐Pallares Approach [PDF]
Mediastinal cryobiopsy is emerging as a powerful adjunct to traditional EBUS‐TBNA, offering larger, architecturally preserved tissue samples. We describe a case demonstrating successful mediastinal cryobiopsy using the newly developed UCP190F ...
Sammy Onyancha, Gernot Rohde
doaj +3 more sources
Background: Transbronchial lung cryobiopsy (TBLC) is frequently described for the diagnosis of diffuse parenchymal lung diseases (DPLD). A few studies have reported transbronchial cryobiopsy for the diagnosis of peripheral pulmonary lesions (PPL...s). We
Sryma Pb, Pawan Tiwari, Karan Madan
exaly +5 more sources
Sequential EBUS-Guided Fine Needle Aspiration and Transbronchial Cryobiopsy for the Diagnosis of a Giant Mediastinal Lipoma: A Novel Intraoperative Pivot Strategy. [PDF]
We report the first case of sequential EBUS‐FNA and an intraoperative pivot to transbronchial cryobiopsy as a rescue strategy for the diagnosis of a giant mediastinal lipoma, with complete pathologic and molecular confirmation. ABSTRACT Mediastinal lipomas are extremely rare, comprising only 1.6%–2.3% of all primary mediastinal tumours, with fewer than
Kanchustambham V, Bowker WE.
europepmc +2 more sources
BackgroundPleural cryobiopsy is a novel technique for the diagnosis of pleural pathologies. However, the safety and feasibility of this modality compared to standard forceps for pleural biopsy has not been fully elucidated.
Shuliang Guo +2 more
exaly +3 more sources
A Novel Dual-Scope Method for Safe Endobronchial Ultrasound-Guided Transbronchial Mediastinal Cryobiopsy. [PDF]
Endoscopic view of the dual‐scope method. An endobronchial ultrasound (EBUS) scope and a thin bronchoscope are simultaneously inserted without intubation. The main monitor displays the EBUS image, while the sub‐display shows the thin bronchoscope image.
Suzuki M +4 more
europepmc +2 more sources
Impaction of an Endobronchial Watanabe Spigot Within a Tracheostomy Tube. [PDF]
We describe a case of endobronchial Watanabe spigot (EWS) impaction within a tracheostomy tube, a complication not previously reported. This case highlights the importance of follow‐up imaging and careful inspection of tracheostomy tubes for possible spigot impaction.
Fukaya T +3 more
europepmc +2 more sources
Isolated Mediastinal and Hilar Lymphadenopathy as a Manifestation of IgG4‐Related Disease Diagnosed by EBUS‐Guided Transbronchial Mediastinal Cryobiopsy [PDF]
Immunoglobulin G4‐related disease (IgG4‐RD) is a fibroinflammatory condition that can involve multiple organs, including mediastinal lesions. Transbronchial mediastinal cryobiopsy has recently emerged as a novel sampling technique that improves ...
Wen Zhang +7 more
doaj +2 more sources
Cryobiopsy is an emerging tool in the diagnosis of peripheral pulmonary lesions (PPL) and becoming an important tool in the toolbox. Anecdotally the data on cryobiopsy use in the lung was extrapolated from the use of transbronchial cryobiopsy (TBCB) in ...
Samantha Herath
doaj +1 more source
Background and study aims Indeterminate biliary strictures represent a major challenge in clinical diagnostics. Diagnostic yield of radiological, endoscopic imaging and histopathological diagnosis is insufficient. The cryobiopsy technique is a new method
Lukas Wirsing +8 more
doaj +1 more source
Thoracoscopy under local anaesthesia is effective for the diagnosis of tuberculous pleurisy (TP), mesothelioma and pleural metastases of lung cancer, etc.
Satoru Ishii +5 more
doaj +1 more source

