Results 11 to 20 of about 785 (181)
A high efficiency hybrid stirling-pulse tube cryocooler
This article presented a hybrid cryocooler which combines the room temperature displacers and the pulse tube in one system. Compared with a traditional pulse tube cryocooler, the system uses the rod-less ambient displacer to recover the expansion work ...
Xiaotao Wang +6 more
doaj +2 more sources
Servo Navigation and Phase Equalization Enhanced by Run-Time Stabilization (PEERS) for 3D EPI Time Series. [PDF]
Purpose To enhance time‐resolved segmented imaging by synergy of run‐time stabilization and retrospective data‐driven phase correction. Methods A segmented 3D EPI sequence for fMRI time series is equipped with servo navigation based on short orbital navigators and a linear perturbation model, enabling run‐time correction for rigid‐body motion, bulk ...
Riedel M +3 more
europepmc +2 more sources
Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure. [PDF]
Gepta‐EX is a compact seven‐channel high‐purity germanium detector designed to deliver high‐resolution fluorescence X‐ray absorption fine‐structure measurements at photon energies where silicon detectors become effectively transparent. It provides excellent energy resolution across a broad energy range, avoids silicon escape‐peak artifacts, and offers ...
Rumaiz AK +6 more
europepmc +2 more sources
Thermal Design of a Protomodel Space Infrared Cryogenic System [PDF]
A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cryocooler has been designed. The PSICS has an IR sensor inside the cold box which is cooled by a stirling cryocooler with refrigeration capacity of 500mW at 80K in a vacuum vessel.
Hyung Suk Yang +6 more
doaj +1 more source
Analysis of the operating parameters in a Stirling cryocooler [PDF]
In this work, the results obtained in different tests performed on a Stirling cryocooler are shows, as well as a comparative analysis of these results with different load pressures.
Maldonado Aguilar Diego José +3 more
doaj +1 more source
Superconducting Surge Current Limiter
A superconducting fault current limiter (SFCL) for medium voltage networks cooled by a cryocooler was designed, built and tested by the current author. For the construction of this limiter, a high-temperature second generation superconducting tape (HTS ...
Sławomir Kozak
doaj +1 more source
High/low temperature setups for submillimetric samples under various extreme conditions at the AILES beamline. [PDF]
Two complementary high‐ and low‐temperature experimental setups have been developed at the AILES beamline of Synchrotron SOLEIL to enable infrared and terahertz spectroscopy of submillimetric samples under extreme and well controlled pressure and temperature conditions (from 10 K to 600 K and from vacuum up to 100 GPa).
Taverna C +8 more
europepmc +2 more sources
ERBIUM AND ITS APPLICATION IN MODERN TECHNOLOGY
Erbium is used as a component of magnetic alloys; oxide of erbium is used in nuclear power to improve energy distribution and safe operation of a nuclear reactor.
A. V. Vasilyeva, A. A. Getman
doaj +1 more source
Gamma-spectrometric module based on HPGe detector for radiation portal monitors [PDF]
The appearance of small-sized and powerful enough electric cryocoolers of various types on the market, has opened the perspective of HPGe detectors application, cooled by such coolers, in radiation portal monitors.
Kondratjev Vladimir +2 more
doaj +1 more source
Numerical analysis of a novel miniature Joule-Thomson cryocooler
In this paper, a novel miniature Joule-Thomson (J-T) cryocooler was proposed and its steady-state cooling characteristics were analyzed via CFD numerical simulation.
Zhicheng Pan +6 more
doaj +1 more source

