Results 91 to 100 of about 1,884,621 (299)

Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The GAFCHROMIC LD‐V1 radiochromic film is widely used in dosimetry because it can provide high‐resolution two‐dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low‐energy range of mammography to the high‐energy range of computed tomography. Net
Tatsuhiro Gotanda   +9 more
wiley   +1 more source

AAPM medical physics practice guideline 13.a: HDR brachytherapy, part B

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract The goal of this report is to assist the clinical medical physicist in assuring that key quality standards and practice considerations are met to ensure safe, reliable, and reproducible high dose rate (HDR) brachytherapy (BT) treatment. This guideline has been developed to provide appropriate minimum standards for such services.
Susan L. Richardson   +8 more
wiley   +1 more source

CÓNDILOS BIFIDO Y TRÍFIDO EN DISFUNCION DE LA ARTICULACIÓN TÉMPORO-MANDIBULAR: REPORTE DEDOS CASOS CLÍNICOS

open access: yesRevista Chilena de Radiología
El cóndilo bífido o trífido es una rara alteración morfológica de las articulaciones témporo-mandibulares (ATM), de etiología desconocida. El objetivo del presente artículo es describirlos hallazgos imaginológicos de dos pacientes que presentan cóndilo ...
Rodrigo Millas M   +6 more
doaj   +1 more source

UR‐cycleGAN: Denoising full‐body low‐dose PET images using cycle‐consistent Generative Adversarial Networks

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to develop a CycleGAN based denoising model to enhance the quality of low‐dose PET (LDPET) images, making them as close as possible to standard‐dose PET (SDPET) images. Methods Using a Philips Vereos PET/CT system, whole‐body PET images of fluorine‐18 fluorodeoxyglucose (18F‐FDG) were acquired from 37 patients to ...
Yang Liu, ZhiWu Sun, HaoJia Liu
wiley   +1 more source

Demonstration of an enhanced dosing pattern for debulking large and bulky unresectable tumors via differential hole‐size spatially fractionated radiotherapy

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose/objective We propose a novel lattice deployment for spatially fractionated radiotherapy (SFRT) treatments. In this approach, a larger diameter high‐dose sphere is centrally placed in the bulky tumor mass and surrounded by smaller diameter high‐dose spheres.
Joshua Misa   +2 more
wiley   +1 more source

Radiotherapy medical physics in the Philippines: A contemporary overview

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose With cancer ranking as the third leading cause of death in the Philippines and a disparity in healthcare resources across regions, this research aimed to assess the state of radiotherapy medical physics in the country. Methodology The study utilized a comprehensive online survey with 94 structured questions answered by 19 clinics ...
John Paul C. Cabahug   +4 more
wiley   +1 more source

Localization accuracy of 6‐second CBCT for lung IGRT with various breathing patterns

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The 6‐second cone beam computed tomography (CBCT) acquisition of the Ethos HyperSight (Varian Medical Systems, Inc. Palo Alto, CA, USA) on‐board imaging system offers benefits, but could be too fast to accurately capture an average target position in a free‐breathing lung cancer patient. This study aimed to ascertain whether a 6‐second
Jihye Koo   +5 more
wiley   +1 more source

The Merchant Shipping Act 1970 * [PDF]

open access: bronze, 1971
Norman Lewis
openalex   +1 more source

Home - About - Disclaimer - Privacy