Log file‐based quality assurance method for respiratory gating system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon   +7 more
wiley   +1 more source

OSTEOMA OSTEOIDE: RESECCION PERCUTANEA GUIADA POR TOMOGRAFIA COMPUTADA

open access: yesRevista Chilena de Radiología
La resección percutánea del osteoma osteoide es una técnica de radiología intervencional que ha empezado a ser utilizada en forma más frecuente.
Enrique Bosch O   +6 more
doaj   +1 more source

Advantages and limitations of navigation‐based multicriteria optimization (MCO) in selectively sparing pharyngeal constrictor muscles in head and neck radiotherapy treatment planning

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Sparing pharyngeal constrictor muscles (PCMs) during radiotherapy improves patient‐reported swallowing function. This study aimed to explore the feasibility of integrating knowledge‐based planning (KBP) with multicriteria optimization (MCO) in Eclipse v18.0 to selectively spare PCM, quantify the required trade‐off in prophylactic ...
Laura K. Howard   +3 more
wiley   +1 more source

The edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley   +4 more
wiley   +1 more source

Primary Renal Carcinoid Tumor Mimicking Non-Clear Cell Renal Cell Carcinoma: A Case Report

open access: yes대한영상의학회지, 2016
Carcinoid tumors are neoplasms with neuroendocrine differentiation, and they are most commonly found in the gastrointestinal and respiratory systems. Primary renal carcinoid tumor has rarely been reported.
Leehi Joo   +3 more
doaj   +1 more source

Producing high quality cranial SRS plans with 4Pi planning technique in a commercial clinical solution

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To generate high‐quality stereotactic radiosurgery (SRS) plans for single cranial lesions using 4Pi planning technique and compare these to our clinical “status quo” plans. Methods Eighteen vestibular schwannoma (VS) patients previously planned with Varian Eclipse RapidArc and treated on a Varian TrueBeam using 6FFF MV photon beams ...
Ganesh Narayanasamy   +4 more
wiley   +1 more source

Melorheostosis: a rare entity: a case report

open access: yesThe Pan African Medical Journal, 2014
Melorheostosis is a rare entity belonging to the group of sclerotic bone dysplasias. Described for the first time in 1922 by Leri, it remains imperfectly known as clinical presentations are highly variable, and the etiological diagnosis is not fully ...
Abdelhakim Kherfani, Hachem Mahjoub
doaj   +1 more source

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source