Results 1 to 10 of about 1,227,308 (328)

DETECTION OF CURRENT CIRCUITS FAULT FOR DIFFERENTIAL CURRENT PROTECTION

open access: yesИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика, 2018
False operation of the differential current protection leads to tripping of the most important electrical power objects. Fault of current transformer’s secondary circuits is one of the most often cause of false operation of the differential current ...
M. S. Loman, V. S. Kachenya
doaj   +3 more sources

Adaptive Current Differential Protection Method Considering Control and Protection Coordination

open access: yesZhongguo dianli
The VSC-HVDC transmission system for large-scale new energy has become a typical scenario in China's new power system. However, the transmission line between the new energy station and the flexible direct converter is special with its both sides being ...
Bo ZHANG   +3 more
doaj   +2 more sources

The study on the Mal-operation of the transformer current differential protection during external faults cause by CT saturation [PDF]

open access: yesE3S Web of Conferences, 2021
This paper analyses the unusual mal-operation of the differential protection for transformer current differential protection during the external fault. The mal-operation reason is researched in detail, based on the mathematical analysis, the simulation ...
Wu Jianhong   +5 more
doaj   +1 more source

Analysis of an accident of abnormal increase in pole bus differential current caused by DC line faults

open access: yesAIP Advances, 2023
This paper analyzes an accident of abnormal increase of pole bus differential current and pole differential current of a converter station caused by line fault of a ±800 kV extra high-voltage direct current transmission project.
Xingyang Hu   +5 more
doaj   +1 more source

Simulation of longitudinal differential protection of transmission lines with additional stabilization and APU system [PDF]

open access: yesTehnika, 2016
This paper explains the algorithm for the longitudinal differential protection of transmission lines with automatic reclosing. Classic stabilization is not sufficient for avoiding of unnecessary operations caused by saturation of current transformer ...
Rajić Tomislav D., Stojanović Zoran N.
doaj   +1 more source

Engineering application research on differential protection of distribution network based on 5G communication

open access: yesZhejiang dianli, 2023
There is a difficulty in setting the coordination of over-current protection in the distribution network with distributed power sources and widely laying optical fiber for differential protection in the distribution network, the study on engineering ...
CHEN Yongkui, LI Hongmei, ZHU Jihong
doaj   +1 more source

A novel protection strategy for DC microgrid considering communication failure

open access: yesEnergy Reports, 2023
DC microgrid has become an important part of supporting “carbon peaking, carbon neutralization” and building a low-carbon energy system. However, the short-circuit current of the DC microgrid rises rapidly and has a great impact, threatening the normal ...
Weiliang Zhang, Hui Zhang, Na Zhi
doaj   +1 more source

All-optical differential current detection technique for unit protection applications [PDF]

open access: yes, 2013
In this paper we demonstrate a novel, all-optical differential current protection scheme. By monitoring the optical power reflected from two matched hybrid fiber Bragg grating current sensors and using a simple optoelectronic threshold detector, an ...
Fusiek, Grzegorz   +3 more
core   +1 more source

Optimizing the roles of unit and non-unit protection methods within DC microgrids [PDF]

open access: yes, 2012
The characteristic behavior of physically compact, multiterminal dc networks under electrical fault conditions can produce demanding protection requirements.
Burt, Graeme   +4 more
core   +1 more source

Consideration of Multi-Phase Criterion in the Differential Protection Algorithm for High-Impedance Grounded Synchronous Generators [PDF]

open access: yes, 2013
The generator differential protection is one of the most important electrical protections of synchronous generator stator windings. Its operation principle is based on the comparison of the input current and output current at each phase winding. Unwanted
Blánquez Delgado, Francisco   +3 more
core   +1 more source