Results 261 to 270 of about 1,227,308 (328)
Some of the next articles are maybe not open access.
Microgrid Differential Protection Based on Superimposed Current Angle Employing Synchrophasors
IEEE Transactions on Industrial Informatics, 2023The inclusion of multi-energy distributed generators (DGs), especially inverter-interfaced generators, presents challenges in the microgrid's protection strategy and operational constraints.
Gagandeep Singh Dua +2 more
semanticscholar +1 more source
Adaptive current differential protection schemes for transmission-line protection
IEEE PES General Meeting, 2009Throughout the history of power system protection, researchers have strived to increase sensitivity and speed of apparatus protection systems without compromising security. With the significant technological advances in wide-area measurement systems, for transmission system protection, current differential protection scheme outscores alternatives like ...
DAMBHARE, S, SOMAN, SA, CHANDORKAR, MC
openaire +2 more sources
Harmonic-current-restrained relays for differential protection
Electrical Engineering, 1938DIFFERENTIAL relaying is the commonly accepted means of protecting large power transformers, a-c generators, and station bus systems against internal faults.1 The methods and circuits employed in various instances, while differing in detail, are all fundamentally the same in basic principle.
L. F. Kennedy, C. D. Hayward
openaire +1 more source
A Novel Current Differential Protection Scheme for Active Distribution Networks
2020 IEEE 3rd Student Conference on Electrical Machines and Systems (SCEMS), 2020Conventiona1 distribution network is supplied from a single source. In such a network, both load current and short-circuit current flow in one direction.
Xueli Guo +7 more
semanticscholar +1 more source
An Integrated Current Differential Protection Scheme
2006 International Conference on Power System Technology, 2006This paper presents a new integrated protection scheme for transmission lines. The concept of the integrated protection is firstly introduced, in which a centralized protection system provides the protection of multiple power plant or a substation. A combined integrated protection relay for the protection of double circuit lines is then introduced ...
H Wang +7 more
openaire +1 more source
A 5G communication based adaptive current differential protection for distribution networks
Information Security Practice and Experience, 2020The fifth generation mobile communication (5G communication) technology provides new ideas for current differential protections of distribution networks by virtue of its advantages in bandwidth, transmission capacity, transmission rate and delay.
Shi Chen +5 more
semanticscholar +1 more source
Modern line current differential protection solutions
2010 63rd Annual Conference for Protective Relay Engineers, 2010Line current differential protection creates challenges for relay design and application. From a design perspective, the distributed nature of the line current differential system imposes limits on the amount of data that can be exchanged between the system terminals and calls for data alignment schemes to enable the differential protection principle ...
Hank Miller +3 more
openaire +1 more source
Backup considerations for line current differential protection
2012 65th Annual Conference for Protective Relay Engineers, 2012Line current differential (87L) protection relies on communications for the exchange of current values and, if applied over asymmetrical channels, on external time sources for current alignment. Proper engineering of 87L schemes calls for a backup strategy that considers the loss of communications and/or the loss of external time sources.
Steven Hodder +2 more
openaire +1 more source
A Fast and Sensitive Current Differential Protection for MMC-HVDC Lines
IEEE transactions on industrial electronics (1982. Print)This article proposes a fast and sensitive current differential protection (CDP) for modular multilevel converter based high voltage direct current lines.
Yuan Nie +5 more
semanticscholar +1 more source
Current-differential protective schemes
1993It will be clear from the previous chapter that overcurrent and earth fault protective equipment employing time grading and directional detection cannot provide correct discrimination on all power networks and in many instances the clearance times for some faults would not be acceptable.
C. Christopoulos, A. Wright