Results 21 to 30 of about 1,227,308 (328)
The high penetration rate of distributed generations (DGs) makes the distribution network’s fault characteristics complex and variable, which limits the application of traditional current differential protection (CDP) in active distribution networks ...
Chengao Yu +3 more
doaj +1 more source
Transmission lines protection based on the current eigenvalues differential concept [PDF]
This work presents a new approach for a current differential protection of the transmission lines. The proposed approach is based on the Clarke-Concordia transformation and principal component analysis.
Fortunato, Carlos +3 more
core +1 more source
A current differential line protection using a synchronous reference frame approach [PDF]
This paper presents a new approach for a current differential protection of the transmission lines. This approach is based on the Park transformation or ABC-dqo transformation.
Fortunato, Carlos +2 more
core +1 more source
All-optical busbar differential protection scheme for electric power systems [PDF]
This paper proposes a novel implementation of a differential protection scheme using magneto-optic current sensors. The proposed all-Optical Differential Protection (ODP) scheme utilizes inherent properties of magneto-optic sensors connected in series to
Dysko, A. +3 more
core +1 more source
The amplitude and phase angle of the fault current in photovoltaic power plants (PVPPs) are significantly influenced by the control system of the grid-connected inverters, unlike in a conventional synchronous source. Hence, PVPPs may adversely affect the
Yingyu Liang, Wulin Li, G. Xu
semanticscholar +1 more source
Protection of power transformer using microcontroller-based relay [PDF]
This paper describes the design and implementation of the micro controller-based system for protecting power transformer. The system includes facilities for discrimination between internal fault current and magnetizing inrush current, differential ...
Bashi, Senan Mahmood +4 more
core +1 more source
The methods of forming differential and restraining currents for busbar differential protection are reviewed; their advantages and disadvantages are considered.
V. S. Kachenya, M. S. Loman
doaj +1 more source
China’s current long-distance offshore wind power mainly follows a high-voltage AC transmission mode with an additional mid-range high-resistance compensation station. With regard to the problem about protection configuration for offshore wind power long-
Zhenlong TAN, Xiangyi QIAN, Wenchang CAI
doaj +1 more source
Comparative analysis of the immune responses induced by native versus recombinant versions of the ASP-based vaccine against the bovine intestinal parasite Cooperia oncophora [PDF]
The protective capacities of a native double-domain activation-associated secreted protein (ndd-ASP)-based vaccine against the cattle intestinal nematode Cooperia oncophora has previously been demonstrated.
Borloo, Jimmy +6 more
core +1 more source
Differential protection strategy for distribution network based on 5G communication
With the high penetration of distributed generation and gradual increase in loop network structures, existing over‐current protection in distribution networks is difficult to apply. The use of current differential protection has become an ideal solution,
Liu Zhiren +6 more
doaj +1 more source

