Results 291 to 300 of about 1,227,308 (328)
Some of the next articles are maybe not open access.
Communication simulation of network based current differential protection
2006 China International Conference on Electricity Distribution (CICED 2006), 2006With the development and wide spread of communication technology and substation automation, it is now possible to implement current differential protection relaying over multiplex fiber optics. Network Simulator is used to simulate and demonstrate the impact of different communication protocals, communication channels, and organization approaches upon ...
null Jianhua Liu +2 more
openaire +1 more source
Novel Sensitive Current Differential Protection of Transmission Line
2008 Joint International Conference on Power System Technology and IEEE Power India Conference, 2008This paper proposes a novel approach for sensitive current differential protection of transmission line. The improvement in sensitivity is a result of adaptive control of the restraining region in a current differential plane. The discriminant function used in differential protection corresponds to the ratio of series branch current in the pi ...
Sanjay Dambhare +2 more
openaire +1 more source
Current transformer saturation detectors for busbar differential protection
2007 42nd International Universities Power Engineering Conference, 2007Busbar differential relays may operate incorrectly due to current transformer (CT) saturation. In this paper two different techniques are suggested to detect CT saturation. The first proposed algorithm is based on the fact that the wave shape of the CT secondary current is changed significantly at the instant of the saturation.
H. Dashti +2 more
openaire +1 more source
Compensated-current differential relay for protection of transformers
IEE Proceedings - Generation, Transmission and Distribution, 2004During magnetic inrush or over-excitation, saturation of the core in a transformer draws a large excitation current, which can cause malfunction of a differential relay. The paper describes a solution, its implementation within a compensated-current differential relay and its evaluation using an EMTP-based simulator and a relay test set. The relay uses
Y.C. Kang +3 more
openaire +1 more source
International Journal of Electrical Power & Energy Systems, 2022
Chenghan Zhou +3 more
semanticscholar +1 more source
Chenghan Zhou +3 more
semanticscholar +1 more source
A Novel Current Differential Protection Scheme for Powerformer
2006 International Conference on Power System Technology, 2006This paper presents a novel differential protection of power former, a type of high-voltage graded insulated cable wound generator. The false differential current associated with the distributed capacitance of power former stator windings is analyzed.
Qing Tian, Xiangning Lin, Wenjun Lu
openaire +1 more source
Current-Based Out-of-Step Detection Method to Enhance Line Differential Protection
IEEE Transactions on Power Delivery, 2019Line differential protection provides the most selective protection scheme for transmission lines. It has an acceptable performance in situations which are challenging for the legacy distance protection. Following large disturbances, two or more areas of
S. M. Hashemi, M. Sanaye-Pasand
semanticscholar +1 more source
Multi-zone current differential protection for transmission networks
2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495), 2004The main idea of this paper is to combine the multi-zone operating features of a pilot aided distance scheme with the unit protection features of a current differential relay. The combination, a pilot aided multi-zone differential protection scheme can cope with main or primary relay failure, incorrect measured or communicated data and the problems ...
K. Kangvansaichol, P.A. Crossley
openaire +1 more source
A transmission line current differential protection based on virtual restraint current
2015 IEEE Power & Energy Society General Meeting, 2015Current differential protection widely used in transmission line based on comparing sum and difference of two side current phasors. Its sensitivity was impact by load current. A current differential protection based on virtual restraint current was proposed.
null Xingguo Wang +2 more
openaire +1 more source
Simulation of a differential current protection scheme involving multiple current transformers
IEEE Transactions on Power Delivery, 2000Differential protection schemes for busbars, generators or transformers connect multiple current transformers in parallel across a common burden. This paper describes the techniques used to simulate such an arrangement and concentrates particularly on the three current transformer case.
U.D. Anndkkage +4 more
openaire +1 more source