Results 21 to 30 of about 929,929 (317)
DETERMINING A TYPE OF A DAMAGE IN THE CURRENT PROTECTION OF POWER LINES OF 6–35 KV
The methods to identify types of phase-to-phase short circuits that can be used to improve technical excellence by speed-current line protection of distribution networks of 6–35 kV are considered.
F. A. Romaniuk +3 more
doaj +1 more source
The paper raises a variant of architecture of realization of logical line protection on the basis of implementation of modern technologies. The idea of development and implementation of digital substations, the core of which is the application of IEC ...
D. A. Davydov +3 more
doaj +1 more source
A novel chopping current protection circuit for intrinsically safe power supply
For problems that traditional chopping current protection circuit had small cut-off current value and poor anti load impact ability, and needed additional recovery circuit or manual circuit after over-current fault, a novel chopping current protection ...
FANG Xupeng +4 more
doaj +1 more source
Designing the Current and Voltage Measuring Instrument for the Impressed Current Cathodic Protection [PDF]
The buried underground or underwater metallic parts suffer from the chemical or hydrochemical corrosion effect.In this paper the later effect will be studied that is caused by the current generated between the metal parts ( the positive pole ) and the ...
Mudfar A. AL-Nemaa +2 more
doaj +1 more source
ABSTRACT Pediatric gastroenteropancreatic neuroendocrine neoplasms (GEP‐NENs) are extremely rare and clinically heterogeneous. Management has largely been extrapolated from adult practice. This European Standard Clinical Practice Guideline (ESCP), developed by the EXPeRT network in collaboration with adult NEN experts, provides (adult) evidence ...
Michaela Kuhlen +23 more
wiley +1 more source
DETECTION OF CURRENT CIRCUITS FAULT FOR DIFFERENTIAL CURRENT PROTECTION
False operation of the differential current protection leads to tripping of the most important electrical power objects. Fault of current transformer’s secondary circuits is one of the most often cause of false operation of the differential current ...
M. S. Loman, V. S. Kachenya
doaj +1 more source
ABSTRACT Background Parents of children treated for acute lymphoblastic leukemia (ALL) often experience significant caregiver burden and disruption to their well‐being. While parent quality of life (QoL) during treatment is well characterized, little is known about outcomes during early survivorship.
Sara Dal Pra +3 more
wiley +1 more source
New optical differential protection algorithm applied in bus protection
In order to improve the speed and reliability of bus protection, people put forward the optical current transformer (OCT) replaced the traditional electric–magnetic current transformer.
Zhu Sitong +4 more
doaj +1 more source
ABSTRACT Background L‐asparaginase is a critical component in treatment protocols for pediatric acute lymphoblastic leukemia. Acute pancreatitis reactions can necessitate delays and, in some cases, discontinuation of L‐asparaginase, which compromises outcomes.
Edward J. Raack +39 more
wiley +1 more source
Reciprocal control of viral infection and phosphoinositide dynamics
Phosphoinositides, although scarce, regulate key cellular processes, including membrane dynamics and signaling. Viruses exploit these lipids to support their entry, replication, assembly, and egress. The central role of phosphoinositides in infection highlights phosphoinositide metabolism as a promising antiviral target.
Marie Déborah Bancilhon, Bruno Mesmin
wiley +1 more source

